BMS001 and BMS002 Stepper Motor Controller
Home Settings
When homing, a stage typically moves in the
reverse direction to the reverse limit switch (as
indicated by the factory set defaults). To
accomodate stages that can home to both Forward
and Reverse limits, the following parameters are
available.
Home Direction
The direction sense to move
when homing, either ‘Forward’
or ‘Reverse’.
Home
Lim.
Switch The hardware limit switch
associated with the home
position, either Forward HW or
Reverse HW.
Home Velocity
The maximum velocity (in real
world units) at which the
motors move when Homing.
(Acceleration is determined by
the Velocity settings).
Zero Offset
The offset distance (in real
world units) from the physical
limit switch to the Home
position.