Appendix B ’SNMP Management’ — Monitoring Tests
Amethyst III DTV Smart Switch
257
User Manual
The
changes counter
is incremented for each input each time an error
occurs on a test. You can thus easily monitor the inputs and see which
ones changed.
Figure B-16. Changes counter
In the example above, 9 errors are detected on ASI input 1 (ID = 31).
The
Tests counter
tables let you see, for each test and each input, the
number of errors that occurred. One table is available for each test level.
Figure B-17. Tests counter table
In the example above, on ASI input 1 (ID = 31), 1 error occurred on Level 1
Test 1.