© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany
021821/08/21
Tel. +49 551 79001-0 · Fax +49 551 79001-65 · [email protected] ·
Page 47 of 102
6.1.1 Recommendations SD-CARD
Notes on SD card:
Not all cards available on the market can be tested for compatibility with the Data logger.
Problems can therefore arise in rare exceptional cases.
The SD cards must be formatted with the standard “FAT16”-, “FAT32”- or “ExFAT” format
(delivery state of SD cards).
6.2 Data Output via COM1, COM2 and Micro USB
Data is output via the interfaces COM1, COM2 and micro USB using the
individually for each average and/or extreme value archive.
The following table shows the possible parameters of the command.
Parameter
Example
Meaning
1
AV1
Stating of the archive with 3 and/or 4 places (“AV1” to “AV16” or
“EX1” to “EX16”)
2
1
170529101000
Start point of the form YYMMDDHHNNSS
(YY: year, MM: month, DD: day, HH: hours, NN: minutes, SS:
seconds)
3
1
170530101000
End point of the form YYMMDDHHNNSS
(YY: year, MM: month, DD: day, HH: hour, NN: Minute, SS:
seconds)
Table 6: Data output with command DS
1)
: The parameters start and end point are optional.
The archived measured values are output in lines, in so-called data rows. The data output is
concluded by the end line.
Note:
Only data lines are written in the output via SD card (writing of the day file). The end line is
only output with the command DS.