User Manual 

DAS30 / DASSO / DAS60 

High Speed Multi-Function Recorders 

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 

Summary of Contents for BK Precision DAS30

Page 1: ...User Manual DAS30 DASSO DAS60 High Speed Multi Function Recorders Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Page 2: ...lso accompanied by a maximum voltage of the circuit to be tested which defines the voltage impulses expected and required insulation clearances These categories are Category I CAT I Measurement instruments whose measurement inputs are not intended to be connected to the mains supply The voltages in the environment are typically derived from a limited energy trans former or a battery Category II CA...

Page 3: ...or flammable atmosphere Do not operate the instrument in the presence of flammable gases or vapors fumes or finely divided particulates The instrument is designed to be used in office type indoor environments Do not operate the instrument In the presence of noxious corrosive or flammable fumes gases vapors chemicals or finely divided particulates In relative humidity conditions outside the instrum...

Page 4: ... the covers are removed To avoid injuries always disconnect the power cord from the instrument disconnect all other connections for example test leads computer interface cables etc discharge all circuits and verify there are no hazardous voltages present on any conductors by measurements with a properly operating voltage sensing device before touching any internal parts Verify the voltage sensing ...

Page 5: ...ected to a circuit being tested Safety Symbols Symbol Description indicates a hazardous situation which if not avoided will result in death or serious injury indicates a hazardous situation which if not avoided could result in death or serious injury indicates a hazardous situation which if not avoided will result in minor or moderate injury Refer to the text near the symbol Electric Shock hazard ...

Page 6: ...he battery 14 2 8 2 Safety precautions 14 2 9 Offset calibration 14 2 10 Default calibration 15 2 11 Screen brightness 15 2 11 1 Locking of the recorder 16 2 12 User mode 16 2 13 Update of the internal software 16 3 Home Screen 17 4 Setup Screen 19 4 1 Logic channels 20 4 2 Real time on screen display of the measurements 21 4 3 XY display 24 4 4 Digital display 24 4 5 Trigger menu 25 4 6 Memory ou...

Page 7: ...tion 45 9 5 Automatic automatic stop when the block is full 45 9 5 1 Creation of the template 45 9 6 Use of the template 46 10 Power Analysis Mode 47 10 1 Power Analysis 47 10 2 Network setup 48 10 3 Wiring and check 49 10 4 Fresnel diagram 50 10 5 Warning messages 50 10 6 Recording additional channels 50 10 7 Real time display of the signals 50 10 8 Power analysis setup 52 10 9 Parameter acquisit...

Page 8: ...2 Logic inputs 71 14 2 1 Use 72 14 3 Alarm outputs 72 14 3 1 Use 72 14 4 Power supply output 72 14 5 External voltage box input output interface 73 15 Ethernet Interface 75 15 1 General 75 15 1 1 Crossover cable 75 15 2 WIFI interface 75 15 3 FTP transfer 76 15 4 Managing with VNC 77 15 4 1 Changing the password 77 15 4 2 External software VNC Viewer 77 16 Programming 78 16 1 Message Format 78 16 ...

Page 9: ...9 17 Specifications 81 18 LIMITED TWO YEAR WARRANTY 82 19 Service Information 83 ...

Page 10: ...ignals Use quick short data acquisition transient Enables complex triggers of the data acquisition action after the end of the data acquisition simulta neous record on file 1 1 3 Go No Go mode Quick acquisition into internal memory of the measured signals Use quick short data acquisition transient for capture of non repetitive events Enables complex triggers particularly when outrunning a pre reco...

Page 11: ...ment independent from the resistance of the line Current You can make current measurements by shunt between the red and black terminals of the rel evant input In this case select the current type among the parameters of the relevant channel Connect the measurement wires to the terminals of the shunt The results are directly displayed in Amperes or milliamperes according to the caliber of the se le...

Page 12: ...ds is recommended If the source of the signal you have to record has low internal impedance use twisted wires For high impedance signal sources using shielded wires is recommended When gathering grounds from the various items on the measurement line it is good to check that there is no voltage difference between them in order to prevent any shortcut If any doubt make a measurement with a voltmeter...

Page 13: ...sult in the absence of any printing out 2 5 2 Storing Printed Recordings In order to maintain the quality of the paper recordings the following is recommended Avoid using laminated sleeves Store away from light in a dry and cool place Store in a carboard sleeve 2 6 Power up Configuration At power up the recorder will be configured how it was when it was shut down If it becomes inconsistent the rec...

Page 14: ... charger starts loading the battery the green light of battery charge will light Charging may be done when it is on or off When the battery is full the green light turns off automatically The recorder can run from AC power indefinitely 2 8 2 Safety precautions Never heat up or expose the battery to fire Never shunt parts of the battery risk of explosion Do not puncture the battery Do not dismantle...

Page 15: ... Default calibration To return the instrument to the factory calibration values use the Recover factory calibration function 1 Go to the setup menu 1 Press 2 Press 2 From setup go to calibration 1 Press 2 Press 3 Press Recover factory calibration and confirm the operation by pressing the green check mark 2 11 Screen brightness Screen brightness is set in the setup screen under Additional Options 1...

Page 16: ...ion settings leaving other menus available The password is Sefram 2 13 Update of the internal software Software updates to the recorders may be available These updates are available on the Sefram website in the Software Updates section Only update the recorder when connected to power and or with a charged battery http www sefram com en software updates html 1 Copy the file to USB stick 2 Plug the ...

Page 17: ...16 Numeric Display 7 Setup Screen 17 Logic Channel Status 8 Channel Setup 18 Analog Channel Status 9 Triggers 19 Screen Capture Button 10 Channel On Off Menu Figure 3 1 Home Screen Pressing the buttons on screen activates the different modes and menus Some areas like the Analog Channel Status on the left side of the screen also have areas within them to open configuration screens For example when ...

Page 18: ...18 Figure 3 2 Single Analog Channel Configuration Screen Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Page 19: ...ddress TCP IP calibration of the channels update of the internal software Figure 4 1 Setup Screen 1 Language 2 Screen shutoff time setting 3 System time settings 4 Graphic Options The display orientation of the data in the bargraph Item 15 Right Max value to the right Left Max value to the left ...

Page 20: ...etwork Setup and status of network communication 12 Alarm Setup and status of the alarm outputs A B C or D 13 Alarm setup keys 14 Logic channel status and states 15 Bargraph showing live measurements 4 1 Logic channels The 16 logic channels can be recorded simultaneously with the analog channels To set the parameters of the logic channels you can press the logic channels menu on the main window or...

Page 21: ...2 Real time on screen display of the measurements 1 Screen configuration configuration of the display of measurements on screen Selection of the mode of graphic display F t XY Digital measures full screen Full screen to display the reticule on the whole screen mode f t Colors to customize the display background reticule cursor Graphic option Custom reticule 2 Channels validation Validation of the ...

Page 22: ...22 Figure 4 4 Figure 4 5 You get access to ...

Page 23: ...tle the time base 3 Math Makes it possible to display values of mathematical calculations on screen 4 Access to the channel configuration page Figure 4 6 1 Screen setup configuration of display of measurements on screen Selection of the graphic display mode F t XY Digital measures full screen Full screen to display the reticule on the whole screen mode f t Colors to customize the display backgroun...

Page 24: ...ration of the display of measurements on screen Selection of the mode of graphic display F t XY Digital measures full screen Full screen to display the reticule on the whole screen mode f t Colors to customize the display background reticule cursor Graphic option Custom reticule 2 Plot starts or stops of the plot 3 Delete erases the screen 4 X channel selection of the channel on the horizontal axi...

Page 25: ...t and validation of the save in real time Figure 4 9 The program of triggers is different according to the pending mode Direct Memory File or Template See the chapter of the pending mode for more details 4 6 Memory output key Display on screen of the data acquisitions available from the internal memory or from files of the internal memory or an USB stick Test Equipment Depot 800 517 8431 99 Washin...

Page 26: ...ve the current display into a file When the size of the data acquisition to display is big it may take time to recover and display the dots The display is made in 2 phases A quick phase to display the frame of the data acquisition some dots may not appear A slower phase where all data acquisition dots are displayed the advancement percentage is displayed at the bottom of the screen 4 7 Record key ...

Page 27: ...acquisition shows up at the top of the screen with the pending block number if relevant the current sampling rate the status of the data acquisition stand by pending xx the opening of a save file if relevant a bargraph specifying the percentage of data acquisition achieved and the percentage of data acquisition displayed 4 8 Screen copy You can create a file copying the content of the LCD screen Y...

Page 28: ...USB copy the selected file or directory to an USB peripheral Type the name of a new file Create directory creation of a new directory you can type its name with the alphanumerical keyboard displayed on screen Erase erases the selected directory or file Close the window Directory Selection Allows you to select the directory to work with 8 Selection of the file window Allows you to select the file t...

Page 29: ...e device in Manual mode after a data acquisition in Real Time during a data acquisition Manual Available under every mode you can access it from the function after stopping 1 Read block lire un bloc mémoire 2 Selection of the block to read 3 Read a recorded file 4 Write data into a file Record the data displayed on screen into another file 5 Close the window Real time Available in Direct Memory an...

Page 30: ...y of the data acquisition files Press from the main menu then The following window pops up Select The following window pops up Select the place and the name of the file to load and display on screen then press Operating software Data acquisition files may be transferred to a PC computer The SeframViewer software is provided on a CD ROM with the device It makes it possible to display the recorded f...

Page 31: ...use them with the SeframViewer or FLEXPRO software 6 Display under SeframViewer Launch SeframViewer or double click on a file Open a REC file You can select the channels to display the display mode f t or xy the autocalibration of the channels Your data acquisition file shows up on screen SeframViewer functions are available Refer to the user s manual included in the software to discover all funct...

Page 32: ...32 Manage setups creation and change setup files Start and stop records Load data blocks Load files thanks to Windows Explorer through FTP Launch SeframViewer Real time display of data in F t format ...

Page 33: ...the printing Press Programming the start and stop conditions of the print Selection of the actions after print and validation of the save in real time Figure 6 1 F t printing a graph as a function of time Digital printing digital values of the measurements as a table 2 Paper speed printing speed You can change it from 10mm min to 20mm h 2 Print configuration see chapter 4 2 3 Start start condition...

Page 34: ... a file Simultaneous save saving or not the simultaneous save File record to a file o Name of the file directory and name of the saving file o Acquisition period sampling rate of the channels o Length of the max file See chapter File mode to know the restrictions of the recording on file If an initial scroll speed has been programmed the paper will scroll at that speed while waiting for a trigger ...

Page 35: ... each channel same as on screen at the end of the print Notes possibility to write notes while printing without at the beginning of the printing on alarm on a length of paper 6 2 1 Relaunching the printing In relaunch mode as soon as stop conditions happen the device waits for new start conditions for the print out To terminate the cycle you only have to force the interruption of the print by pres...

Page 36: ...he setup screen see Figure 7 1 Figure 7 1 Memory Mode Setup 1 Blocks parting of the internal memory in blocks 1 2 4 8 16 32 64 or 128 Erase blocks erasing of all blocks the current block is 1 2 Acquisition period sampling rate of the channels internally paced from 1µs to 10min externally paced by the logic channel 16 3 Start start condition of the data acquisition Manual with the key Trigger with ...

Page 37: ...ate or the number of channels See chapter File mode to know the restrictions of the recording on file 7 2 Sampling period When the frequency of the input signals is too high to record them in Direct mode you must record the measurement signals into memory at high sampling rate it is the Memory mode Sampling consists in recording the instant value of a signal at regular intervals and storing each o...

Page 38: ...e start moment You can also not inhibit the trigger you will be able to test the trigger during the pre trigger phase in case the trigger should happen before the end of this phase In case of repetitive signals the trigger should be inhibited Delay to memory input 50 Delay to memory input 50 from the 1st position of buffer from the 1st position of buffer 7 5 Double Trigger mode In this mode you wi...

Page 39: ...ge of menu Figure 7 3 For longer acquisition time you can zoom onto a part of the data or change of page When changing of menu page you can return to data acquisition by pressing Figure 7 4 Additional menu keys Display Total the whole memory is displayed and refreshed during the data acquisition Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Page 40: ...acquisitions Figure 7 5 1 Read blocks or file selection of the memory block or of the file to display if there is no valid block the only menu key available will be Load file 2 Screen setup type of display diagrams see chapter Use 3 Time cursors vertical cursors zoom 4 Voltage cursors horizontal cursors 5 Zoom between cursors allows a zoom between the positioned cursors 6 Zoom Zoom allow zooming o...

Page 41: ...41 the date of trigger the number of points per channel in the block a bargraph showing the filling level of the block and the position of the trigger ...

Page 42: ...ame of the data acquisition file 2 Acquisition period sampling speed of the channels internally paced from 1µs to 20min externally paced by the logic channel 16 3 Start start condition of the data acquisition Manual with the key Trigger with a channel with a combination of analog and logic channels see chapter 5 Stand by after a delay or at a precise date and time 10 2 File Mode Automatic 4 Stop s...

Page 43: ...rnal memory or USB sticks It is advisable no to create too big files because reading them may be very long It takes ca 3 minutes to read a 200MB file The minimum transfer rate to the flash disk is 100 Kwords s 10µs To know the number of channels you can record at a given acquisition period calculate number of channels 100 000 x acquisition period example at 20µs the number of channels is max 2 ...

Page 44: ...s onto a file can be activated 9 1 Setup and launching of the data acquisition Press Setup of the data acquisition as a template into internal memory Figure 9 1 9 2 Blocks parting of the internal memory in blocks 1 2 4 8 16 32 64 or 128 Erase blocks erasing of all blocks the current block is 1 1 Acquisition period sampling speed of the channels internally paced from 1µs to 20min externally paced b...

Page 45: ...mpossible shows up when there is not enough place for saving data you should reduce the sampling rate or the number of channels See chapter File mode to know the restrictions of the recording on file 9 5 1 Creation of the template Make a data acquisition into memory Press then select The device displays the current template It is marked as 2 curves a min curve and a max curve around the channel se...

Page 46: ...ction of the acquisition speed position of the trigger as a function of pre trigger phase Figure 9 3 The comparison to the template is only possible when the channels are validated for data acquisition An error message shows up if you have selected Template Channels that have note been validated The data acquisition is made as above see chapter Memory Mode When the memory block is full the device ...

Page 47: ... the various measurements voltage current power 1 Measurement mode of the current clamp shunt transformer 2 Parameters of the current measurement conversion from the measured value and the value sent to the recorder 3 Nominal current in the phase conductor 4 Wiring scheme 5 Logic channels validation and parameter setting 6 Display of the measured values 7 Phase diagram 8 Type of network 9 Paramete...

Page 48: ...s the DAS60 should be strictly connected to its external power supply and connected to the socket this for security reasons ensuring earthing 10 2 Network setup In the main menu change of mode by pressing You directly access the setup page Select the basis configuration of the network single phase three phase mode Aaron Only 2U and 2I are used The 3rd phase is re calculated method of the double wa...

Page 49: ...n each configuration you have to enter the associated parameters For clamp primary current secondary voltage these are current voltage clamps For transformer transformer shunt primary and secondary currents and value of the shunt For shunt value of the shunt in ohms You also have to set the nominal current and voltage Data acquisitions are synchronized with the calculation of frequency of channel ...

Page 50: ...wirings must be made with caution by a qualified personal 10 5 Warning messages Messages may appear in red any time at the top of the screen Impossible to synchronize the signal the frequency is wrong the signal is too weak or too noisy Caliber exceeded The voltage or the current are too high for the theoretical nominal value you must change this value or use another probe 10 6 Recording additiona...

Page 51: ...scilloscope This mode allows you to know the true shape of the signals hence it will help you detect wiring mistakes The time basis depends on the frequency of the signal at least one alternation You can change the reticules and the position of the displayed channels Harmonic display This window is updated ca once a second ...

Page 52: ...B stick by pressing 10 8 Power analysis setup Press to open the setup menu Once the device is set up you still have to set the type of measurement to make you can make a power analysis or an energy analysis Figure 10 8 10 9 Parameter acquisition file You should first set the sampling period and the directory of the file There is no trigger as soon as the record is launched the values of the parame...

Page 53: ...ed according to a TRUE condition of a given parameter of a value and of a comparison You will find the list of the parameters you can use at 10 11 You can select a stop condition recording time or manual stop Figure 10 9 10 11 1 Trigger according to an inrush You can start the record according to an inrush current and select a stop condition recording time or manual stop Figure 10 10 ...

Page 54: ...rom 1 to 14 Selection of values you can select 10 12 1 Voltage and Current Efficient RMS efficient value o Fund fund efficient value of the fundamental o Average dc average value DC offset o Peak cr maximum value between the max and min peaks Peak factor fcr ratio between the peak value and the efficient value 1 414 for a sinusoidal signal Total harmonic distortion THD ratio of the total presence ...

Page 55: ... the caliber shall be 400V centered on 200V hence between 0 and 400V the minimum and maximum values may be changed for finer display For example you will be able to display the signal U1 between 220V and 240V 10 13 Record You launch the data acquisition by pressing There is no trigger the record is made in real time directly on the disk During the data acquisition you cannot change the parameters ...

Page 56: ...2 𝑡 𝑋2 𝑓𝑢𝑛𝑑 𝑋2 𝑡 Total Active Power 𝑃𝑇 𝑃1 𝑃2 𝑃3 Total Reactive Power 𝑄𝑇 𝑄1 𝑄2 𝑄3 Total Apparent Power 𝑆𝑇 𝑃2 𝑇 𝑄2 𝑇 Total Voltage 𝑈𝑇 𝑈2 1 𝑈2 2 𝑈2 3 3 Total Intensity 𝐼𝑇 𝐼1 𝐼2 𝐼3 Power Factor 𝐹𝑃𝑇 𝑃𝑡 𝑆𝑡 Energy cumulative value of power P this value is reset in the Visualization page Attention the maximum value of energy during the data acquisition is restricted to E Pn H where Pn nominal power H 12 h...

Page 57: ...or the selected channel You can also change this thickness with the thicker keys 1 Checkbox to validate a threshold 2 Current threshold value or change of the threshold value 3 Information about the channel caliber thresholds offset 4 Logic inputs real time status of the logic inputs By pressing the menu channels you access the table of all available analog and temperature channels of your recorde...

Page 58: ...hannel at the top of the table A1 A2 or by pressing on the bargraph of the channel right side of the screen 11 1 Analog channels Figure 11 4 1 Number of the channel 2 Name of the channel give a name to the channel max 26 characters 3 Type selection of the type of measurement made on the input voltage current frequency thermocouple or counter direct RMS ΔV Δt or 𝑉 𝑑𝑡 value of the shunt for current ...

Page 59: ...ters and unit 𝒂𝑿 𝒃 identical to the change of units but instead of giving a couple of dots you give the intercept b and the slope a 𝑿 𝒃 absolute value 𝒂𝑿𝟐 𝒃 square 𝒂𝒍𝒏 𝑿 𝒃 Naperian logarithm 𝒂 𝑿 𝒄 𝒃 square root 𝒂𝒄𝒙 𝒃 natural exponential 𝒂 𝟏 𝑿 𝒃 reverse 10 Copy to channel makes it possible to copy the adjustment of a given channel onto one or several other channels 11 Display window for the thresho...

Page 60: ...se 11 2 1 Example Channel 1 triangle signal 5V to 5V period 5s Channel 2 use measurement type ΔV Δt with the same signal ΔV 10V Δt 50ms Span 20V s The signal Channel 1 is varying linearly at 4V s and then at 4V s The derivative Channel 2 give 4V s and 4V s 11 2 2 Type of measurement 𝑉 𝑑𝑡 𝑉 𝑑𝑡 Put on the measurement type integral If U is the voltage measurement every period dt the recorder calculat...

Page 61: ...square signal period 10s 2s at 5V 8s at 0V Channel 2 use measurement type V dt with the same signal V 10V dt 200 µs Span 200Vs The signal integral channel 2 begin at 0Vs and then increase of 10Vs integration of 5V during 2s every signal Channel 1 period ...

Page 62: ...or calculations of average values For example if you want to calculate a value of power select the parameters of the A function channel Figure 11 9 You get this page above Then you make the calculation you want by pressing the formula bar and create the calculation you want in the following window For the calculation of power you will have a x y b with x channel A1 operator unit W y channel A2 coe...

Page 63: ...63 Figure 11 10 ...

Page 64: ...ly have level triggers Analog Logic channels trigger only from analogic or logic channels Single Multiple threshold triggering from only one threshold or complex triggering from several channels and several thresholds see description below Such complex triggering is only possible with analogic channels You can setup these triggers thanks to the trigger menu in the homepage Figure 12 1 12 1 Analog ...

Page 65: ...er Lower trigger when the channel value is more or less than the set threshold 4 Threshold value threshold value selected in real value taking the current unit and scale of the configuration of the selected channel into account 5 Edge Selection of the active edge of the channel in reference to the threshold 12 1 2 Multiple thresholds After selection of a trigger on a set of logic channels the wind...

Page 66: ... is valid for the AND trigger all thresholds OR 12 1 4 Parasites You can trigger a parasite with a periodic 50Hz signal trigger when the shape of the signal radically changes parasite impulsion 200µs sudden change of frequency Figure 12 4 12 1 5 Trigger on Logic Channels After selection of the trigger on Logic Channels the window allows you to set the trigger condition The 16 logic channels can be...

Page 67: ...67 Figure 12 5 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Page 68: ...ion applied in the formula You can change it by pressing directly on the type which opens a window with all available calculations 18 various mathematical formulas are available You can display up to 5 simultaneous calculations on screen The display is made in windows above the diagrams where are specified the number of the channel with its color the type of calculation the value of calculation Un...

Page 69: ... values click and drag them to a desired position on screen Minimum Maximum Peak to Peak Low The most frequent value below the median High The most frequent value above the median Amplitude On positive oscillation 𝑀𝑎𝑥 𝐻𝑖𝑔ℎ 𝐴𝑚𝑝𝑙𝑖𝑡𝑢𝑑𝑒 100 On negative oscillation 𝐿𝑜𝑤 𝑀𝑖𝑛 𝐴𝑚𝑝𝑙𝑖𝑡𝑢𝑑𝑒 100 Average frequency 1 𝑃𝑒𝑟𝑖𝑜𝑑 ...

Page 70: ...ve pulse width Measurement of the time of 1st positive pulse It is measured at 50 of amplitude Negative pulse width Measurement of the time of 1st negative pulse It is measured at 50 of amplitude Positive duty cycle positive pulse duration 𝑝𝑒𝑟𝑖𝑜𝑑 Negative duty cycle negative pulse duration 𝑝𝑒𝑟𝑖𝑜𝑑 N total number of dots 1 𝑁 𝑁 𝑖 1 𝑉𝑖 Note2 RMS 1 𝑁 𝑁 𝑖 1 𝑉𝑖 2 Note2 Standard Deviation 1 𝑁 𝑁 𝑖 1 𝑉𝑖 𝑉 2...

Page 71: ...ogic channel 7 22 I Logic channel 8 9 I Logic channel 9 21 I Logic channel 10 8 I Logic channel 11 20 I Logic channel 12 7 I Logic channel 13 19 I Logic channel 14 6 I Logic channel 15 18 I Logic channel 16 5 Ground 17 Ground 4 Ground 16 O 9 15V 0 2A power 3 Ground 15 Alarm C 2 Alarm D 14 O Alarm A 1 O Alarm B The power supply ground is the mechanical ground of the carter of the SUB D25 connector ...

Page 72: ...channel 16 see figure connector as a data acquisition clock for the sampling in memory or file mode The data acquisition can then be made up to 500kHz Triggers You can use the logic channels to trigger the plotting and the data acquisitions start and stop AND or OR mode See chapter Trigger 14 3 Alarm outputs Available contacts and outputs on the rear connector A B C and D All outputs are TTL 5V Wh...

Page 73: ...nel 1 0 to 48V by a screw terminal between the points 1 and 3 of the screw terminal box max usable voltage 48V AC or DC frequency 45 to 440Hz typical trip threshold AC or DC 9V undetected low threshold AC or DC 0 to 2V detected high threshold AC or DC 10V to 48V insulation 50V between channel and ground 0 to 10V 1 2 connection 0 10V logic channel 1 by a screw terminal between the points 1 and 2 of...

Page 74: ...74 Figure 14 3 ...

Page 75: ...e set up the recorder with the key turn off and on the device so that the changes are taken into account If you don t have any network administrator Check that the TCP IP driver is correctly installed on your device Case of a PC under Win XP or other From Windows Explorer go to Work station Configuration panel network connection and then go to the properties of the network card Check that the TCP ...

Page 76: ...s several times When your network appears select it and validate The commands are automatically positioned You only have to type the password In case of connection problem contact your network administrator Figure 15 2 In the setup page you will get the IP addresses of the Ethernet and Wi Fi networks Figure 15 3 15 3 FTP transfer Transfer your files to your computer to save them or view them with ...

Page 77: ...l time while recording it 15 4 Managing with VNC This piece of software allows you to manage the recorder remotely 15 4 1 Changing the password In the Setup page press VNC You can then change the password of VNC The default password is sefram 15 4 2 External software VNC Viewer You are submitted a link to easily download this software http www realvnc com download viewer Select the exe file You on...

Page 78: ...cimal format except 10 and 13 Example of messages made with 3 message units MESSAGE 1 MESSAGE 2 MESSAGE 3 TERM CHANNEL 1 TYPE VOLTAGE DC CALDEC TERM 16 3 Message Syntax A message ex REAR SETUP 1 is made of several fields 16 3 1 Header For the command messages ex REAR SETUP 1 or query messages ex REAR it is made of a chain of characters simple header or several chains separated by compound header A...

Page 79: ...rder to a controller to the recorder are made as messages made of a chain of ASCII characters and possibly of binary bytes with a message termination at the end The format of emission messages is identical to the reception messages although with a more rigid structure The syntax of a response message is Message unit message termination Message unit If the message includes several message units the...

Page 80: ...ed un der ASCII example J Decimal digital data Made of a chain of ASCII characters starting with a cipher or a sign or They are of NR1 integer NR2 decimal or NR3 type with exponent For example for a digital character 25 02 Text data Any chain of ASCII 7 bit characters between brackets or apostrophes Example A Any chain ASCII characters ends with the message termination ...

Page 81: ...ons apply to the unit after 1 A temperature stabilization time of 15 minutes over an ambient temperature range of 23 C 5 C 2 Short correction operation performed before making measurement Specifications are subject to change without notice ...

Page 82: ...300 C C 32 F to 4208 F 0 C to 2320 C L 392 F to 1652 F 200 C to 900 C Power Analysis Function Networks Single phase 3 phase Display Fresnel diagram oscilloscope data Measurements Mean value RMS peak crest factor THD and DF for voltage current active reactive and apparent power power factor ø Harmonics Calculated up to rank 50 with display and record Logic Input Channels 16 TTL Maximum Voltage 24 V...

Page 83: ...instrument via our website www bk precision com Exclusions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs The warranty is void if the serial number is altered defaced or removed B K Precision Corp shall not be liable for any consequential damages including without limitation damages resulting from loss of use Some s...

Page 84: ...83 Service Information Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...