4.5.5 Login Options
The DLU has different access options and logins depending on the configuration and
equipment.
Via the
micro-USB, COM
and
Telnet
access, remote maintenance commands can be
accessed without logging in to read measured values and parameters. To write parameters,
the login command
KY
followed by a key is required. The valid commands and their structure
are described in
Chapter 7
.
For the DLU with Ethernet access, there is also access via
SFTP
to download files and
WEB
pages
to view measured values and make configurations.
Access via
SFTP
is only possible via user logins. No user is configured on delivery. Names
and passwords for
SFTP
access can be assigned via the WEB login
admin
. The
SFTP
access is described in chapter 4.5.2.2.
You can access the homepage for the WEB without logging in. It is sufficient to enter
http: //
followed by the logger IP address in a web browser. To configure via WEB, the configuration
menu must be opened with the administrator login. On delivery, you can access the
configuration menu with
admin
and login
1111
. The WEB Seien are described in detail in
Chapter 8.
Attention:
The administrator login password should be changed during commissioning! The
password must not be forgotten. Otherwise no settings can be made via Ethernet.
User settings can then no longer be changed, not even via the display!