4.5.3.2.3 IP setting via WEB
Does an Ethernet connection already exist e.g. through dynamic IP assignment, the IP
parameters can also be changed via WEB. A computer with a network connection and a
WEB browser, e.g. Microsoft Edge are necessary. In addition, the following steps can be
used to test the DLU's Ethernet access.
Note:
Setting the IP address via WEB is only possible if the DLU already has a valid IP address in
the network, e.g. with dynamic IP assignment.
To do this, proceed as follows:
1. Start the WEB browser
2. Enter in the entry line
http://
followed by the valid IP address of your logger and send
the command by pressing the Enter key.
3. If an error message appears instead of the WEB page, enter http: // again followed by
the IP address and check the entry for errors. If the error persists, check whether you
are using the correct IP for the logger e.g. via the display of the logger and check the
connections.
4. After the start page has loaded successfully, open the Settings menu using the button
, and go to the submenu
to chance the IP address.
5. In the menu you can change the parameters and with
passed to the logger
6. A restart must be carried out for takeover the changes.
The WEB pages are described in Chapter 8.
4.5.4
LAN-Connecting Check
After valid IP parameters have been set on the DLU or in the event of connection problems,
there are several ways to test the LAN connection.
First, the following 3 points should be ensured and checked:
1. All cables should be OK and have correct contact in the socket.
2. The DLU should be switched on and work properly (restart if necessary).
3. IP parameters (address, mask, gate, DNS) should be correctly set (accepted) after
the reset.
If the three conditions are OK, the different connection protocols can be tested with the
following tests.
1. PING-test
2. SFTP-test
3. Telnet-test
4. WEB-test