background image

Qmini series industrial GIS data collector manual

 

- 1 - 

 

 

 

Hi-Target 

 

Qmini Series 

Industry GIS Data Collector 

Manual

 

 

 

Manual Revision 

 

 

Revised 

Date 

Revised 

Times 

Specification 

July/2010 

Qmini Series Industrial GIS data collector manual 

1.0 Version 

 

 

 

Summary of Contents for Qmini Series

Page 1: ...rial GIS data collector manual 1 Hi Target Qmini Series Industry GIS Data Collector Manual Manual Revision Revised Date Revised Times Specification July 2010 1 Qmini Series Industrial GIS data collector manual 1 0 Version ...

Page 2: ...i Series Industrial GIS Data Collector 9 3 3 Reverse of Qmini Series Industrial GIS Data Collector 9 3 4 Interface 10 3 5 Touch Pen Appearance 11 3 6 Battery 11 3 7 Data Cable 12 3 8 Strap 12 Chapter 4 Basic Operation 13 4 1 Introduction 14 4 2 Keyboard 14 4 3 Touch pen 14 4 4 3G card 15 4 5 MicroSD card 16 4 6 Power Supply system 17 4 7 Turn on or turn off Qmini Series industrial GIS data collect...

Page 3: ...Qmini series industrial GIS data collector manual 3 Chapter 1 Preface Chapter Instruction Instruction Relative Information Technical Support Your Suggestions C H A P T E R 1 ...

Page 4: ... 1 2 Relative Information You can get the manual from the following 1 the supplementary CD when purchasing Hi Target Qmini series equipment You can get this manual from folder named Manual 2 Download from Hi Target website Go to Download Section Products Manual GIS products 1 3 Technical Support You can find Technical Support in Hi Target website You can contact our technical center or service dep...

Page 5: ...Qmini series industrial GIS data collector manual 5 Chapter 2 Summary Chapter Introduction Instruction Product Features Usage and Notes C H A P T E R 2 ...

Page 6: ...nd software package And it can satisfy second development equipment of customer and software provider Tips This manual is for Qmini Series Industry GIS Data Collector product functions will be different according to different model please refer to technical parameters Before using we suggest users firstly to check whether the package box is damaged and then open careful and check whether inner ite...

Page 7: ...e Industry GIS Data Collector must be used and stored in the specified temperature More details please refer to Chapter 5 Technical Parameters To ensure the quality of continuous tracking satellites and signals surveying station s top should be in open while there should no any obstacle in space above 15 altitude angle in order to reduce all kinds of electrical interference to the GNSS satellite s...

Page 8: ...apter 3 Qmini Series Introduction Chapter Introduction Introduction Obverse side of Qmini Series Industrial GIS Data Collector Inverse side of Qmini Series Industrial GIS Data Collector Interface Touch Pen Appearance Battery Data Wire Strap C H A P T E R 3 ...

Page 9: ...Touch Screen 3 5 inch upright screen directly touch to operation support Chinese and English input Protective cover wear prevention anti drop anti shock avoid being scratched Key board Direction key enter key escape key power and other function keys Microphone build in microphone can be used for voice information collection on the spot 3 3 Reverse of Qmini Series Industrial GIS Data Collector Figu...

Page 10: ... the performance of the instrument after water happens to go into speaker But please drying the speaker in time 3 4 Interface Figure 3 3 shows the location of interface for Qmini Series Industrial GIS Data Collector Its functions are Charging data transferring SIM installation and SD cards for the Interface Figure 3 3 interface Figure 3 4 interface inner SIM card slot install SIM card MicroSD card...

Page 11: ...right corner of GIS data collector and the length can be changeable according to the requirements figure 3 6 Figure 3 5 Touch Pen Figure 3 6 Touch Pen 3 6 Battery Figure 3 7 Figure 3 8 Obverse and inverse side of 2000mAh lithium battery Figure 3 7 Obverse of battery Figure 3 8 inverse of battery Tip To protect the environment please do not throw the useless lithium battery away optionally please s...

Page 12: ... industrial GIS data collector USD interface connect with USB port of PC to download data Warning To prevent damage the plug store the cable in good place after using without squeezing 3 8 Strap Due to smaller stature of Q mini please put your hand through the strap to prevent falling during the operation work Figure 3 10 Strap USB interface Data collector port ...

Page 13: ...lector manual 13 Chapter 4 Basic Operation Chapter Introduction Introduction Key board Touch Pen 3G Card Micro SD card Power Supply System Turn on off Qmini Series Industrial GIS Data Collector Data Acquisition Application C H A P T E R 4 ...

Page 14: ...ndicate cancel or quit the current operation Ent Enter F1 Function key Function is defined by the software Please refer to the software manual Power on off key Hold this key one second power on Three seconds or above power off Switch on off backlight after power on Microphone Built in microphone can be used for voice message collecting Tips IF you don t use Qmini series GIS Data Collector in work ...

Page 15: ...d Qmini 3P 1 Install the 3G card Gently dig the yellow protective cover of interface there is an oblong open mouth as card socket Figure 4 4 installation diagram 2 Figure 4 4 there is a yellow button in the left of 3G card Press it and the 3 G card s cassette will be popup take the card out install the 3G card in the cassette Listen to the sound which plastic spring stuck It shows that installing ...

Page 16: ...is an oblong open mouth as MicroSD card socket Please noted the MicroSD card s metal surface should upward Plug the MicroSD s card to plughole until the MicroSD is completely in the plughole The edge of MicroSD is parallel to the card trough Figure 4 9 MicroSD card 2 Take out the MicroSD card Firstly push the card forward the card will be popup half automatically take MicroSD out Tips MicroSD card...

Page 17: ...ng the sound of plastic spring sticking It shows installing already Remove 1 See chart 4 11 according to the direction to take out the battery Figure 4 11 remove battery 2 Listen to the sound of gently dig plastic take out the battery Qmini series GIS Data Collector battery and charger s model Power supply mode Name Model 2000mah lithium battery BL 2000A Lithium Battery charger CL 2000A Power supp...

Page 18: ...hen using it first should use the power up then recharge with first three times should charge for 12 hours after third time should charge for 4 hours If the battery often do not use must charge once a month Figure 4 12 charging diagram Figure 4 13 Charging diagram Figure 4 14 finish charging diagram When charging the battery click Start Setup Control Panel power can check the remaining battery rea...

Page 19: ...ase change the battery 3 Please stop to use the battery if the using time is obviously short means the battery is aging and please change the battery 4 7 Turn on or turn off Qmini Series industrial GIS data collector Turn on 1 Press 1 second industrial GIS data collector will go into BIOS screen put off the button BIOS will automatically upload to Windows system be patient to wait for about 10 sec...

Page 20: ...en follow the instruction to finish installing After installing run the Microsoft ActiveSync in Start menu Program Setup Allow to connect by USD in the Connect setup Figure 4 18 Figure 4 18 USB connecting setup 2 Hardware connect Turn on the Qmini series industrial GIS data collector go into Windows system no need to open Application program Connect Qmini series industrial GIS data collector with ...

Page 21: ... GIS data collector see figure 4 20 go into NandFlash related directory to copy the data to your computer Figure4 20 WinCE Asset Browser Screen Tips The collecting data or new installing software must save in NandFlash or MicroSD card otherwise industrial GIS data collector data will be lost after Re start 4 9 Application Function Qmini series industrial GIS data collector adopts PPP technology Th...

Page 22: ...Qmini series industrial GIS data collector manual 22 Chapter 5 Technical Parameter Chapter Introduction Introduction Technical Data C H A P T E R 5 ...

Page 23: ...essor RAM 128MB SDRAM 512M Flash memory built in Flash memory support 1G Display professional colorful touch screen for outdoors GPS features 20 channel GPS 16 channel L1 carrier phase GPS Support SBAS WAAS EGNOS MSAS High sensitive anti interference GPS antenna built in Update rate 1Hz Update rate 4Hz First positioning time 30 seconds typical Positioning Accuracy Single point positioning 5 m SBAS...

Page 24: ...ule supporting remote wireless communications built in 3 million pixels camera alone with image marking function Built in Mic With voice marking function Supporting vehicle navigation software installation GPS bracket and car charger are optional Physical Properties Size 14 8 3 5cm Weight 360g incl battery Working temp 30 70 Storage temp 40 80 Water dust proof standard IP67 Anti shock withstand 1 ...

Reviews: