Initializing the Micro-Tech
Initializing the Software
2-36
Micro-Tech 9101/9201 Reference Manual, Rev J
Thermo Fisher Scientific
3.
Press the Manual button and the following screen appears.
NOTE.
The belt must be running
empty
and at maximum speed during
the procedure to establish the appropriate test time. Pressing the Abort
button at any time returns you to the “Establish Test Duration”
screen.
4.
Start the belt and, when it is running at maximum speed, press the
Continue button. The following screen appears. (The default value is
200 feet.)
5.
Press the Edit button and use the keypad to enter the length of the
belt. (We entered 120 feet, as described in our example on page 2-
11)
BATCH
Start belt. Press
CONTINUE when belt
is at maximum speed
READY
ALARM
CALIB
CONTINUE
ABORT
BATCH
Ent. len. of
one belt revolution
Length 200 ft
READY
ALARM
CALIB
ABORT
EDIT