![Thermo Scientific HB-S2000 Скачать руководство пользователя страница 82](http://html.mh-extra.com/html/thermo-scientific/hb-s2000/hb-s2000_user-manual_1105188082.webp)
Sarasota 2000 Ultrasonic Multipath
Flowmeter
Appendix 1 SCREEN FLOW DIAGRAMS, Page A1-34
Thermo Fisher Scientific
APPENDIX 1 LCD SCREENS
SCREEN S8: DATA LOGGING (ENTRY/EDIT)
(Screen accessed via S0:Station Menu)
S8 Data Logging
Log Id : [abc123]
Logging Interval:30 seconds
Log Wrap : yes
Source Index
Var 1 :Flow Channel1 []
Var 2 :Cumulative Channel1 []
Var 3 :Velocity Channel1 []
Var 4 :Level Channel1 []
Var 5 :DMD Channel1 []
Var 6 :Temperature Channel1 []
Var 7 :Path Velocity Channel1 []
Var 8 :Path Vos Channel1 []
Var 9 :Path tof Channel1 []
Var 10:Path % good Channel1 []
Var 11:Diff Time Channel1 []
Var 12:iLevel Channel1 []
Station Text Off
DATA LOGGING
Selection :
Logging Interval:
30 seconds
1 minute
5 minutes
10 minutes
15 minutes
30 minutes
off
Selection :
Log Wrap:
Yes
No
Selection :
Log Variable:
None
Flow*
Cumulative*
Velocity*
Level
DMD*
Temperature*
Path velocity
Path vos
Path tof
Path % good
Diff time
iLevel
(those marked * have an index of ‘0’, all other indices relate to individual paths or depths)
Selection: Source:
Station
Channel
1-4
Содержание HB-S2000
Страница 2: ......
Страница 3: ...Sarasota 2000 Ultrasonic Multipath Flowmeter User Guide P N HB S2000 Revision A ...
Страница 4: ......
Страница 6: ...This page intentionally left blank ...
Страница 10: ...Sarasota 2000 Ultrasonic Multipath Flowmeter INDEX Page 4 Thermo Fisher Scientific INDEX This page is blank ...