![Thermo Scientific HB-S2000 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/thermo-scientific/hb-s2000/hb-s2000_user-manual_1105188022.webp)
Sarasota 2000 Ultrasonic Multipath
Flowmeter
Section 2, SYSTEM COMPONENTS, Page 2-4
Thermo Fisher Scientific
SYSTEM COMPONENTS
Fig 2 Sarasota 2000 Flowmeter internal components
Main rack
, from left to right:-
Power supply with fuses and power switches (see 2.3.2.1)
Card position 1 - Status/power management card
Card position 2 - I/O card 1 (if fitted) (see 2.3.3.2)
Card position 3 - I/O card 2 (if fitted)
Card position 4 – Reserved for future enhancements
Card position 5 – Reserved for future enhancements
Card position 6 - TIF 4 (Transducer interface card 4) (if fitted)
For connection to up to 8 velocity paths (16 transducers) via rear panel connectors G
and H, upstream (u/s) and downstream (d/s) and up to 4 ultrasonic depth transducers via
connector Z (see Fig 4 and 2.3.3.1)
Card position 7 - TIF 3 (if fitted)
Rear panel connectors E,F for up to 8 velocity paths and Y for up to 4 depths.
Card position 8 - TIF 2 (if fitted)
Rear panel connectors C,D for up to 8 velocity paths and X for up to 4 depths.
Card position 9 - TIF 1 (always fitted)
Rear panel connectors A,B for up to 8 velocity paths and W for up to 4 depths.
Card position 10 - Central Processor (CPU) (see 2.3.2.2)
The plinth, beneath the main rack, houses the internal battery (see Section 2.3.2.1), the
connectors (see Fig 5) and the relay card.
Note
Power should be switched off and the isolate switch turned off before any cards are
removed or plugged in.
RS232
T3.15A
F5A
MAINS
ISOLATE
Содержание HB-S2000
Страница 2: ......
Страница 3: ...Sarasota 2000 Ultrasonic Multipath Flowmeter User Guide P N HB S2000 Revision A ...
Страница 4: ......
Страница 6: ...This page intentionally left blank ...
Страница 10: ...Sarasota 2000 Ultrasonic Multipath Flowmeter INDEX Page 4 Thermo Fisher Scientific INDEX This page is blank ...