Primary Displays & Menus
The Data Log Menu
The Data Log menu contains the Log Menu (80) and the Log Interval
menu (81). The data logger provides the ability of continuously recording
flow data at a preset interval. The flowmeter has a single data log file with
approximately 30,000 data points available. This allows considerable data
to be collected. For instance, if collecting data at a 60-second interval, the
flowmeter could store data for approximately 20 days. The data logger is
always enabled (always recording data). When all 30,000 points are
recorded, the data logger records over the previous data points one at a time
in a continuous loop, starting with the oldest data points first.
The Data Log
Menu
he Data Log
Menu
The log file can be transferred in ASCII format to a PC for record keeping
or analysis. In addition, the data log file can be deleted by resetting the data
point values to zero. Log files are transferred using the D-Link flowmeter
data link utility (refer to
Appendix D
).
●
Data Log setup menu (80)
The only option available in this menu is
Interval
. Select this to enter
the next menu.
Figure
5–60.
Data Log setup menu
●
Data Log Interval menu (81)
Data log intervals must be entered in whole seconds, with a minimum
interval of 1 second.
Figure
5–61.
Data Log Interval menu
Caution
The data logger automatically deletes data whenever the log
interval, data, time, flow units, pipe dimensions, or liner dimensions are
changed.
▲
Any power interruptions cause zeroes to be written in the data log stream.
This feature is useful to determine if an interruption in the time sequence
has occurred or if the instrument has been moved or tampered with while
logging data.
Thermo Fisher Scientific
DCT6088 User Guide
5-25
Содержание DCT6088
Страница 2: ......
Страница 3: ...DCT6088 Dedicated Transit Time Flowmeter User Guide P N 1 0561 006 Revision J ...
Страница 4: ......
Страница 6: ...This page intentionally left blank ...
Страница 8: ...This page intentionally left blank ...
Страница 12: ...This page intentionally left blank ...
Страница 20: ...This page intentionally left blank ...
Страница 78: ...This page intentionally left blank ...
Страница 94: ...This page intentionally left blank ...
Страница 97: ...Pipe Schedules Table A 2 Cast iron pipe standard classes Thermo Fisher Scientific DCT6088 User Guide A 3 ...
Страница 98: ...Pipe Schedules A 4 DCT6088 User Guide Thermo Fisher Scientific Table A 3 Ductile iron pipe standard classes ...
Страница 118: ...This page intentionally left blank ...
Страница 120: ...This page intentionally left blank ...