32
Pin 8:
C
lear
T
o
S
end
The signal is used to tell the system device connected to the
transceiver that the transceiver is ready to receive data. When
asserted, the transceiver will accept data, when de-asserted
the transceiver will not accept data. This should always be
used for data rates above 38.4 Kbaud or there will be a risk of
lost data if an RF link is not very robust.
Pin 9: Not used
14.0 DATA COMMUNICATIONS SETTINGS
The device to which AutoWAVE is connected should be configured to match the settings
shown in Table 13.
Parameter
Setting
Baud Rate
Match to AutoWAVE
Data Bits
8
Parity
None
Stop Bits
1
Parity Check
None/Off
Carrier Detect
None/Off
Flow Control
RTS/CTS/Hardware
Connection Started by
Carrier Detect
Connection Ended by
Carrier Detect
DTR Signal
Always On
RTS Signal
Always On
Table 13: Data Communication Settings.