All installations and services must be performed by qualified service personnel.
4
Direct (Side-Wall) Venting
The furnace may also be horizontally vented through a sidewall. Thermo Products has available
the side wall vent kits for such applications. When installing the sidewall vent kits, outside
combustion air must also be applied to the burner. The following table identifies application
order information.
Table 2: Sidewall vent kits
The vent may be installed either through the knock-out on the right or left side casing of the unit
or vertically out the top opening of the vestibule.
The combustion air inlet can be installed through the either the lower left side casing knockout or
the lower right side casing knockout.
Power (Side-Wall) Venting – Important Note Regarding
c
CAUTION: Thermo Products, LLC will NOT assume responsibility for damage to, and
deterioration of, exterior building materials, e.g. brick, siding, clapboards, and etc., in close
proximity to the vent terminal due to operation of a power vented, oil furnace. This policy
is applicable regardless of the cause of sooting.
Two (2) problems typically arise when power venting any oil-fired appliance.
1)
Soot buildup may occur at an accelerated rate on critical components of the furnace oil
burner, e.g. the primary control flame sensor (“cad cell”), the burner head, and oil nozzle.
2)
Severe damage may occur to external surfaces of the structure in the event the furnace
continually produces a high level of smoke in the flue gases. Excess smoke and soot can be
produced for many reasons, some of which cannot be successfully controlled by the installer
and the appliance manufacturer.
NOTICE: Thermo Products recommends the use of a chimney to vent residential oil
furnaces. If a power venter must be used, it is the responsibility of the installer and power
venter manufacturer to design, assemble, and demonstrate proper operation of the power
venting system with the furnace.
FIELD VENT TERMINATION
KIT
SIDE WALL VENT
ACCESSORIES KIT
COMBUSTION AIR INTAKE
HOOD KIT
(15’ application MAX)
(BURNER SPECIFIC)
(FOR COMBUSTION AIR
APPLICATIONS ONLY)
THERMO PRODUCTS PART
NUMBER
THERMO PRODUCTS
PART NUMBER
THERMO PRODUCTS PART
NUMBER
(OL6) (OL8)
Beckett AFG
AOPS8393 AOPS8414
AOPS8394
AOPS8397
Riello BF5
AOPS8393 AOPS8414
AOPS8395
AOPS8416
Carlin EZ-1HP
N/A AOPS8414
AOPS8432
AOPS8433
BURNER
Содержание OL6FA072D48B
Страница 2: ......
Страница 27: ...23 All installations and services must be performed by qualified service personnel...
Страница 29: ...25 All installations and services must be performed by qualified service personnel...
Страница 31: ...27 All installations and services must be performed by qualified service personnel...
Страница 33: ...29 All installations and services must be performed by qualified service personnel...
Страница 34: ...30 All installations and services must be performed by qualified service personnel...
Страница 35: ...31 All installations and services must be performed by qualified service personnel...
Страница 36: ...32 All installations and services must be performed by qualified service personnel...
Страница 37: ...33 All installations and services must be performed by qualified service personnel 57...
Страница 38: ...34 All installations and services must be performed by qualified service personnel...
Страница 39: ...35 All installations and services must be performed by qualified service personnel...
Страница 50: ...46 All installations and services must be performed by qualified service personnel OL8RA119T60...