All installations and services must be performed by qualified service personnel.
9
G.
BURNER SPECIFICATIONS AND APPLICATIONS:
Beckett oil burner application
FURNACE
MODEL
THERMO
PRIDE’S
BURNER
SPEC NO.
*
INS
BECKETT
BURNER
MODEL &
TUBE
LENGTH
HEAD STATIC
PLATE
MAXIMUM
NOZZLE
SIZE**
SHIPPED
NOZZLE
SIZE
OIL PUMP
PRESSURE
(PSIG)
OL6*A072D**B TP2501
N
AFG-4.5”
F3
3-5/8
0.75X70° B 0.60X70° B 120
OL8*A119T**B TP2502
N
AFG-4.5”
F6
2-3/4U
1.10X80° A 1.00X80° A 120
Carlin oil burner application
FURNACE
MODEL
THERMO
PRIDE’S
BURNER
SPEC NO.
INS
+
CARLIN
BURNER
MODEL &
TUBE
LENGTH
HEAD STATIC
PLATE
MAXIMUM
NOZZLE
SIZE**
SHIPPED
NOZZLE
SIZE
OIL PUMP
PRESSURE
(PSIG)
OL6*A072D**C 99032B
N
EZ-1HP
4.5”
N/A
N/A
0.75X60° A 0.60X60°A 120
OL8*A119T**C 99032C
N
EZ-1HP
4.5”
N/A
N/A
0.90X60° A 0.85X60° A 140
Riello oil burner application
FURNACE
MODEL
THERMO
PRIDE’S
BURNER
SPEC NO.
INS
+
RIELLO
BURNER
MODEL &
TUBE
LENGTH
HEAD STATIC
PLATE
MAXIMUM
NOZZLE
SIZE**
SHIPPED
NOZZLE
SIZE
OIL PUMP
PRESSURE
(PSIG)
OL6*A072D**R C8511325 S
BF3-4.5”
N/A
N/A
0.70X80° A 0.60X80° A 140
OL8*A119T**R C8512317 S
BF5-4.5”
N/A
N/A
1.00X80° A 0.85X80° A 140
Table 4: Beckett, Carlin & Riello burners specifications
+ INSULATOR S = SLEEVE OR
N = NONE
THE NOZZLE SIZE GIVES THE NOMINAL FLOWRATE, IN GPH, FOLLOWED BY
THE SPRAY ANGLE, IN DEGREE’S, AND THE SPRAY PATTERN, EITHER “A” FOR
HOLLOW CONE OR “B” FOR SOLID CONE. FOR EXAMPLE, A NOZZLE RATED
AT 0.65 GPH @ 100 PSIG THAT PROVIDES AN 80° SPRAY ANGLE AND A HOLLOW
SPRAY PATTERN WOULD BE ABBREVIATED IN THE TABLE AS “0.65 X 80
°A
”.
Содержание OL6FA072D48B
Страница 2: ......
Страница 27: ...23 All installations and services must be performed by qualified service personnel...
Страница 29: ...25 All installations and services must be performed by qualified service personnel...
Страница 31: ...27 All installations and services must be performed by qualified service personnel...
Страница 33: ...29 All installations and services must be performed by qualified service personnel...
Страница 34: ...30 All installations and services must be performed by qualified service personnel...
Страница 35: ...31 All installations and services must be performed by qualified service personnel...
Страница 36: ...32 All installations and services must be performed by qualified service personnel...
Страница 37: ...33 All installations and services must be performed by qualified service personnel 57...
Страница 38: ...34 All installations and services must be performed by qualified service personnel...
Страница 39: ...35 All installations and services must be performed by qualified service personnel...
Страница 50: ...46 All installations and services must be performed by qualified service personnel OL8RA119T60...