All installations and services must be performed by qualified service personnel.
OL6*A072D48
ALTERATIONS REQ’D FOR A/C @ DESIGN EXTERNAL STATIC PRESSURE
COOLING UNIT
HTG Speed by Input
Recommended CLG Speed
Low fire
Mid Fire
High Fire
24,000
ML
MED
MH
Med Low
30,000
ML
MED
MH
Med
36,000
ML
MED
MH
Med High
42,000
ML
MED
MH
High
48,000
ML
MED
MH
High
Speed Tap\ Static
Pressure
Furnace Airflow (CFM) vs. External Static pressure (in. WC.)
0.2
0.3
0.4
0.5
0.6
Low
712
691
682
667
664
ML
902
899
896
883
874
MED
1113
1113
1109
1091
1073
MH
1270
1266
1250
1239
1215
High
1670
1637
1605
1566
1527
Motor Current Draw (Amps/Watts) vs. External Static pressure (in.
WC.)
Low
4.1/408
4.0/398
4.0/395
3.9/385
3.8/378
ML
5.3/540
5.3/535
5.2/527
5.1/512
4.9/500
MED
6.6/665
6.4/644
6.2/634
5.9/609
5.6/584
MH
7.6/772
7.2/739
6.9/713
6.6/682
6.4/663
High
9.6/951
84/830
9.0/887
8.8/869
8.4/835
Speed Tap\ Static
Pressure
High Fire Temperature Rise vs. External Static pressure (in. WC.)
0.2
0.3
0.4
0.5
0.6
Low
119
122
124
127
127
ML
94
94
94
96
97
MED
76
76
76
77
79
MH
66
67
68
68
70
High
51
52
53
54
55
Speed Tap\ Static
Pressure
Mid Fire Temperature Rise vs. External Static pressure (in. WC.)
0.2
0.3
0.4
0.5
0.6
Low
96
99
100
102
103
ML
75
76
76
77
78
MED
61
61
61
62
63
MH
54
54
54
55
56
High
41
42
42
43
45
Speed Tap\ Static
Pressure
Low Fire Temperature Rise vs. External Static pressure (in. WC.)
0.2
0.3
0.4
0.5
0.6
Low
79
81
83
84
85
ML
62
63
63
64
64
MED
51
51
51
52
53
MH
44
44
45
45
46
High
34
34
35
36
37
Appendix – C Airflow Charts
Содержание OL6FA072D48B
Страница 2: ......
Страница 27: ...23 All installations and services must be performed by qualified service personnel...
Страница 29: ...25 All installations and services must be performed by qualified service personnel...
Страница 31: ...27 All installations and services must be performed by qualified service personnel...
Страница 33: ...29 All installations and services must be performed by qualified service personnel...
Страница 34: ...30 All installations and services must be performed by qualified service personnel...
Страница 35: ...31 All installations and services must be performed by qualified service personnel...
Страница 36: ...32 All installations and services must be performed by qualified service personnel...
Страница 37: ...33 All installations and services must be performed by qualified service personnel 57...
Страница 38: ...34 All installations and services must be performed by qualified service personnel...
Страница 39: ...35 All installations and services must be performed by qualified service personnel...
Страница 50: ...46 All installations and services must be performed by qualified service personnel OL8RA119T60...