background image

TECHNICAL GUIDE

AFFINITY 

MODELS: PT8*DH

GAS-FIRED
HIGH EFFICIENCY TWO STAGE 
DOWNFLOW/HORIZONTAL FURNACES
STANDARD & Low NOx 

NATURAL GAS
40 - 120 MBH INPUT

Due to continuous product improvement, specifications 
are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.

Additional rating information can be found at 
www.gamanet.org.

EFFICIENCY
RATING
CERTIFIED

ISO 9001

Certified Quality

Management System

246796-YTG-D-0407

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

These high efficiency, compact units employ induced com-
bustion, reliable hot surface ignition and high heat transfer 
tubular heat exchangers. The units are factory shipped for 
installation in downflow or horizontal applications.

These furnaces are designed for residential installation in a 
basement, closet, alcove, attic, recreation room or garage 
and are also ideal for commercial applications. All units are 
factory assembled, wired and tested to assure safe depend-
able and economical installation and operation.

These units are Category I listed and may be common 
vented with another gas appliance as allowed by the 
National Fuel Gas Code ANSI Z223.1 (latest edition).

WARRANTY

20-year limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applica-
tions.
5-year limited parts warranty.

FEATURES

Two stage heating operation includes:
- Two stage gas valve
- Two stage inducer operation
This provides both increased comfort level and very 
quiet unit operation

Delay timer allows two stage operation with single stage 
thermostat

Acoustically insulated blower compartment for reduced 
blower sound level

Humidifier and Electronic Air Cleaner control wires are 
provided to the power wiring box for easy field connec-
tion.

100% shut off main gas valve for added safety

Rollout safety control

Low unit amp requirement for easy replacement appli-
cation

High quality two speed inducer motor for quiet operation

Built-in self diagnostics with fault code display

40 VA control transformer fuse protected

Cooling relay supplied for easy installation of add-on 
cooling

Multi-speed PSC, direct-drive blower motor to match 
cooling requirements

Adjustable fan-off settings to eliminate "cold-blow"

Compact 40-in. height allows installation in small space 
confines

All models are propane convertible

Low NOx models have been designed to meet specific 
code requirements.

Low NOx models may not be converted to propane 
unless screens are removed.

Summary of Contents for PT8DH

Page 1: ...ce as allowed by the National Fuel Gas Code ANSI Z223 1 latest edition WARRANTY 20 year limited warranty on the heat exchanger 10 year heat exchanger warranty on commercial applica tions 5 year limited parts warranty FEATURES Two stage heating operation includes Two stage gas valve Two stage inducer operation This provides both increased comfort level and very quiet unit operation Delay timer allo...

Page 2: ...H11 2000 C 21 19 3 4 18 1 2 13 1 2 RATINGS PHYSICAL ELECTRICAL DATA MODEL Input High Low Output BTU H High Low Nominal Airflow Cabinet Width AFUE Blower Blower Size MBH MBH CFM In Hp Amps In PT8A12 N L 040DH11 57 42 46 34 1200 14 1 2 80 0 1 2 7 7 10 x 8 PT8A12 N L 060DH11 80 59 64 48 1200 14 1 2 80 0 1 2 7 7 10 x 8 PT8A12 N L 080DH11 80 59 64 48 1600 17 1 2 80 0 3 4 9 6 10 x 10 PT8B16 N L 080DH11 ...

Page 3: ...910 810 680 560 Low 980 970 960 930 890 830 760 680 550 450 PT8B16 N L 080DH11 High 2070 2000 1930 1850 1770 1670 1580 1470 1360 1250 Medium 1650 1630 1610 1560 1490 1420 1360 1270 1170 1040 Low 1410 1400 1370 1340 1320 1270 1210 1140 1050 950 PT8C16 N L 080DH11 High 1895 1812 1736 1624 1544 1437 1311 1153 1032 836 Medium 1726 1645 1581 1491 1412 1311 1192 1049 908 750 Low 1561 1493 1430 1373 1304...

Page 4: ...ween filter manufacturer NOTES 1 Air velocity through throwaway type filters may not exceed 300 feet per minute All velocities over this require the use of high velocity filters RECOMMENDED FILTER SIZES CFM Cabinet Size Top Return in 1200 A 2 14 x 20 1600 B 2 14 x 20 1200 B 2 14 x 20 1600 C 2 14 x 20 2000 C 2 14 x 20 FILTER PERFORMANCE PRESSURE DROP INCHES W C AND KPA Airflow Range Minimum Opening...

Page 5: ...ract the airflow 0 50 from the airflow 0 60 to obtain airflow difference 1170 1240 70 CFM 3 Subtract the total system static from 0 50 and divide this difference by the difference in ESP values in the table 0 60 0 50 to obtain a percentage 0 58 0 50 0 60 0 50 0 8 4 Multiply percentage by airflow difference to obtain airflow reduction 0 8 x 70 56 5 Subtract airflow reduction value from airflow 0 50...

Page 6: ...tion Light E W1 First Stage Heat G Fan G Fan Connection of the C Termainal 24 Volt Common is optional when used with batteries Thermostat Installer Setup Number 1 System Type must be set to 6 2 Heat 2 Cool Conventional R 24 Volt Hot Heat XFMR W2 Second Stage Heat RC 24 Volt Hot Cool XFMR E W1 First Stage Heat G Fan DN22U00124 THERMOSTAT Y2 Second Stage Cool Y2 Second Stage Cool Y First Stage Cool ...

Page 7: ...Bonnet Sensor Bonnet Sensor Optional BS Bonnet Sensor W2 Second Stage Auxiliary Heat W2 Second Stage Auxiliary Heat AUX Auxiliary Heat E W1 First Stage Auxiliary Heat E W1 First Stage Auxiliary Heat W Auxiliary Heat Y2 Second Stage Heat Cool Y2 Second Stage Heat Cool Y2 Second Stage Heat Cool Y2 Second Stage Heat Cool L Malfunction Light L Malfunction Light L Malfunction Light X L Malfunction Ligh...

Page 8: ...o change without notice Printed in U S A 246796 YTG D 0407 Copyright by York International Corp 2007 All rights reserved Supersedes 246796 YTG C 0806 Unitary 5005 Norman Products York OK Group Drive 73069 NOTES ...

Reviews: