background image

Summary of Contents for CFP-200

Page 1: ......

Page 2: ...Cameo Proclain Furnace Operator s Manual Model CFP 200 Cameo Porcelain Furnace Ideal diagnosis and treatment experience...

Page 3: ...nstallation 10 2 6 Active cooling fan 10 2 7 Automatic temperature regulation 10 Chapter 3 Furnace Introduction 11 3 1 Cameo CFP 200 Proclain Furnace 11 3 2 Features 11 3 3 Software 11 3 4 Technical p...

Page 4: ...creen 20 4 10 Vacuum test 20 4 11 Vacuum test interface 21 4 12 Temperature calibration function 22 4 13 Standby temperature setting 23 4 14 Sleep mode interface 24 4 15 Furnace cleaning 24 4 16 Syste...

Page 5: ...information If you have any questions during installation configuration and use please contact us Foreword Dear Users Firstly thank you for purchasing our product Please confirm the furnace according...

Page 6: ...ese personnel must be aware of foreseeable and potential hazards Only designated trained and appointed personnel can complete operation maintenance and repair of the furance These personnel must be in...

Page 7: ...use limitations and related potential hazards of the furnace The hazards caused by the following situations will be very serious Incorrect operation methods or inexperienced operators Failure to comp...

Page 8: ...n normally Once the safety furnace is found invalid faulty it must be replaced in time If it cannot be replaced in time shut down the furnace Before switching on the furnace all protective mechanisms...

Page 9: ...or and obstacles will pose a threat to your safety The most important thing is to ensure that all worktables on the furnace are clean because the dust on them will cause serious wear and fire 1 1 19 P...

Page 10: ...e furnace such as lubrication and adjustment but do not conduct under the working condition Installation maintenance cleaning and removal of the furnace can only be carried out after the power supply...

Page 11: ...working condition The manual includes all technical data required by users for daily operation and maintenance Important safety warning signs are marked on the furnace which are mentioned in many rel...

Page 12: ...Inflammables are strictly prohibited around the furnace 2 2 Idle mode When the furnace is in the idle mode make the working bench return into the furnace and turn off the main switch Close the furnace...

Page 13: ...e is damaged 2 4 Cleaning When cleaning do not clean the upper cover of the furnace with the wet cloth to avoid water dripping short circuit or furnace damage When the fault light is on or the buzzer...

Page 14: ...the silicone hose is sleeved to the root of the joint and ensure the air tightness 3 Insert the power cord of the vacuum pump into the power output interface of the vacuum pump on the back plate of t...

Page 15: ...of 1 Vacuum pump high limit vacuum value maintenance free and large flow Pipeline multi layer filter structure to improve stability and service life of components Vacuum performance vacuum process de...

Page 16: ...Equipment self check to ensure stable operation of various functions Furnace cleaning function 3 4 Technical parameters 1 Dimension 362X316X596mm 2 Net weight gross weight 28KG 34KG 3 Furnace size 95m...

Page 17: ...cord 16A 1 piece 3 Baking forceps hemostatic forceps 1 piece 4 Honeycomb type baking tray 2 pieces 5 Porcelain nails 1 bag 6 Firing platform 1 piece 7 Lifting tray sealing ring 1 piece 8 One operator...

Page 18: ...urrent curve information in real time The status indicator is flashing green 1 is the number of the current curve Cameo1 is the name of the current curve Relevant parameters of the curve and the graph...

Page 19: ...vacuum mode is on Whether the vacuum mode of the current curve program is on or not On is to turn on the vacuum mode Off is to turn off the vacuum mode Start the current firing curve program Display t...

Page 20: ...in real time Cameo1 Cameo2 Biomi c1 Biomic2 Biomic3 Bi omic4 Biomic5 Biomic6 are curve parameters and names configured by factory default which can be modified at will After restoring the default cur...

Page 21: ...of the executed program as well as the remaining time 4 5 Confirm the firing interface and exit it Click to start the current firing procedure Click X to return the main interface Click to exist the f...

Page 22: ...selected Curve Program Start Firing Current Curve Program List 120 Curve Programs You can page up down and click to select one curve to edit or directly start firing 4 7 Curve parameters setting scre...

Page 23: ...indicates the starting temperature of the vacuum pump V Temp End Vacuum Temperature End indicates the temperature at which the furnace is unloaded from vacuum state Rate 2 min Rate 2 indicates the te...

Page 24: ...acuum end temperature is not higher than the maximum procedure temperature Error 6 The vacuum starting temperature is not lower than the starting temperature 4 9 Function setting screen The screen inc...

Page 25: ...to return the vacuum test interface When the vacuum reaches 90 within 120 seconds the vacuum is judged acceptable and prompt the vacuum detection normal When the vacuum does not reach 90 within 120 se...

Page 26: ...he lowest end Place the temperature measuring ring PTCR UTH in the middle of the firing platform and click Confirm After the furnace temperature reaches 800 and retain it for 60 minutes Then the tray...

Page 27: ...control compensation value in the lower left corner or directly set the compensation value compatible with the setting mode of the next generation porcelain furnace which can be ignored by new users 4...

Page 28: ...k on the main interface II After four continuous hours of no operation activities on the main interface 4 15 Furnace cleaning Click Furnace Clean in the function interface the tray will be lowered to...

Page 29: ...16 System setting Click System Setting on the function design interface to enter the system setting interface The system setting interface includes Luminance Volume Button sound State lamp Self test L...

Page 30: ...lf check After starting the furnace self check function manually power off the furnace and restart it and automatically perform the furnace self check Main inspection contents include tray test vacuum...

Page 31: ...interface This version supports 9 languages Simplified Chinese English French Italian German Spanish Portuguese Japanese Korean Click Confirm to save the settings 4 19 Device information Click Device...

Page 32: ...trol error Contact customer service for inspection and maintenance Tray up down error Contact customer service for inspection and maintenance Communication error Contact customer service for inspectio...

Page 33: ...Aidite 29 Vacuum error Please check whether the air seal is damaged or contact customer service for inspection and maintenance Chapter 4 Operation Guidance...

Page 34: ...s performed by Aidite s certified service technicians Repairs performed during the warranty period do not extend the warranty period The warranty period starts from the date when the furnace is first...

Page 35: ...ng time min Starting temperature Temperature rise rate min Maximum temperature Holding time min Opening temperature Slow cooling min Biomic 1 8 450 55 730 1 500 1 Biomic 2 8 450 55 720 1 500 1 Biomic...

Page 36: ...perature 1st stage holding time min 2nd stage temperature rise rate min Biomic7 400 1 40 820 5 20 2nd stage temperature 1st stage holding min Opening temperature Slow cooling min Vacuum start Vacuum e...

Reviews: