CSR-20 & CSR-40, September 1999
µ
P-D Controller
Menu Program Functions
4-41
8.
When the Bulb mode is ON, the defrost termination tem-
perature screen “BDFTT” appears in the Program menu.
To change the defrost termination temperature:
a.
With “BULB ON” in the display, press the DOWN
key to scroll to the “BDFTT” screen. The current set-
ting appears in the right display (factory default is
30.0 C (86.0 F).
b.
Press the SELECT key. “BDFTT” will flash in the
left display.
c.
Press the UP or DOWN key to adjust the defrost ter-
mination temperature to the desired setting (see ship-
ping manifest). The right display scrolls up or down
to the new temperature setting (e.g. “20.0”).
d.
To load the new temperature, press the ENTER key.
The display briefly shows “BDFTT LOAD”.
e.
The display then shows “BEFAN” in the left display
and the current evaporator fan speed selection in the
right display (e.g. “HI”).
9.
When the Bulb mode is ON, the current evaporator fan
speed screen “BEFAN” appears in the Program menu. To
change the fan speed selection:
a.
With “BULB ON” in the display, press the DOWN
key to scroll to the “BDFTT” screen. If a new defrost
termination temperature was set, the “BEFAN”
screen already appears. The current setting appears in
the right display (factory default is HI).
b.
Press the SELECT key. “BEFAN” will flash in the
left display.
c.
Press the UP or DOWN key to adjust the evaporator
fan speed to the desired setting (see shipping mani-
fest): “HI”, “LO” or “CYCLE”.
d.
To load the new setting, press the ENTER key. The
display briefly shows “BEFAN LOAD”. The display
then shows “BEFAN” in the left display and the cur-
rent fan speed selection in the right display (e.g.
“CYCLE”).
NOTE: Press and hold the SELECT key for 3 sec-
onds to return to the Standard Display.
Power Reduction Mode
Changing the Power Reduction program screen from OFF to
ON activates the power reduction control algorithm that
reduces total unit electric power consumption for 8 hours. The
use of the Power Reduction Mode should be established by the
shipper. When the Power Reduction Mode is ON:
•
The controller reduces the electric power consumption by
the percent selected: 10%, 20% or 30%.
NOTE: When the Power Reduction Mode is active,
the controller display will briefly show “PWRED ON”
every 10 seconds.
Setting the Power Reduction Mode
1.
Press the SELECT key to enter menu (display shows
“MENU <--->”.
2.
Press DOWN key until display shows “MENU PRGRM”.
3.
Press the SELECT key to show “PRGRM <--->”.
4.
Press the DOWN key to show the current setting,
“PWRED 0” (OFF); or “PWRED 1”, “PWRED 2”,
“PWRED 3” (ON).
5.
Press SELECT key. “PWRED” will begin to flash.
6.
Press the UP or DOWN key to scroll the right display to
the desired setting:
• 0 = OFF
1 = 10% Power Reduction
2 = 20% Power Reduction
3 = 30% Power Reduction
NOTE: The cooling capacity of the unit may be
reduced when the Power Reduction Mode is
active. The greater the reduction in electric
power (e.g. “2” or “3” setting), the greater the
likelihood of unit cooling capacity reduction. The
use of the Power Reduction Mode should be
established by the shipper.
7.
Press the ENTER key to load the power reduction setting
selected. The display briefly shows “PWRED LOAD”.
Left display then shows “PWRED” and the right display
shows the new power reduction setting (e.g. “1”).
NOTE: Press and hold the SELECT key for 3 sec-
onds to return to the Standard Display.