4-4
Controller Display Menus
µ
P-D Controller
CSR-20 & CSR-40, September 1999
Pause Mode Displays
WARNING: When the unit is in the PAUSE mode, the
compressor, evaporator fans or condenser fan may
continue to operate or start at any time without
notice.
A Pause mode display appears when the controller interrupts
normal unit operation to perform a check or test. For example,
the Pause mode display for a Shutdown alarm condition is
show below.
Pause Condition Display/Description
Phase Check
“PAUSE CHECK”/During initial unit
start-up, the controller checks the power
phase sequence for correct compressor,
condenser fan and evaporator fan rotation.
Sensor Check
“SENSR CHECK”/If the supply and
return air temperature difference is outside
certain limits during cooling and no alarms
are recorded, the controller performs a
Sensor Check test.
“SENSR XXX”/Shows the time remain-
ing on the current Sensor Check test being
performed.
Alarm Shutdown
“PAUSE ALMXX”/Stops unit operation
due to a shutdown alarm condition. A 2-
digit alarm code (“XX”) appears in Pause
display to identify the alarm condition.
Typically the condenser fan continues to
operate while the controller attempts to
correct the condition and restart the unit.
The Pause mode display continues until the
shutdown condition has been corrected.
IN RANGE
DEFROST SUPPLY RETURN PWRLMT ALARM
HEAT
NULL
MOD
COOL
SETPOINT
TEMPERATURE
DATA
DATA
View Menu
Menu screens in this group are used to display unit operating
information, sensor grades and scrollback data logger data
including controlling sensor temperatures and pretrip test
information. No changes can be made to the data from the
View menu.
Pretrip Menu
Menu screens in this group are used to activate pretrip tests
including Extended Pretrip Test, Full Pretrip Test and Single
Pretrip Tests.
Test Menu
Menu screens in this group are used to set the unit to specified
operating conditions for system and component diagnostics.
Guarded Access Menu
Access to the menu is protected by a special security code.
Menu screens in Guarded Access are used to set the unit con-
figuration, time and date and sensor grades; enter container ID
number and unit serial number; and change programmable set-
tings via keypad.
Program Menu
Menu screens in this group are used to activate the USDA sen-
sors, Pulp sensor, Economy mode, Dehumidify mode (and
enter humidity setpoint), Bulb mode (and enter defrost termi-
nation temperature and evaporator fan motor speed), or Power
Reduction mode.
Menu Display Definitions
Acronym
Definition
ALM
Alarm
ALMXX
Alarm 01, 02, 03 ...XX (total number of recorded
alarms).
ALOGS
Data Logs in (P-A+ Format on Auxiliary Battery
Power (Option)
AMBT
Ambient Temperature Sensor
AMP1
Total Current Phase A
AMP2
Total Current Phase B
AMP3
Total Current Phase C
AMPS
Amperage
AMTG
Ambient Temperature Sensor Grade
AUXV
Auxiliary Battery (Option) Voltage
BEFAN
Bulb Mode Enable Fan
BDFTT
Bulb Mode Defrost Termination Temperature