4-30
Menu Guard Functions
µ
P-D Controller
CSR-20 & CSR-40, September 1999
NOTE: If the correct code is not entered, the dis-
play returns to “GUARD <--->”.
6.
Press the DOWN or UP key to scroll through the menu list.
NOTE: If a new controller or new software has
been installed, proceed immediately to “Setting
the Unit Configuration and Customer
Configuration Numbers” below.
NOTE: If no key is pressed, the controller returns
to the “GMENU <--->” display from a Guard Menu
screen after 30 seconds. The display returns to
the Standard Display 10 seconds later.
Setting the Unit Configuration and
Customer Configuration Numbers
1.
From “GMENU <--->” in the Guard menu, press the
DOWN key until the display shows “MENU CNFIG”).
2.
Press the SELECT key to enter Configuration submenu
(display shows “CNFIG <--->”).
3.
Press the DOWN key until display shows “CFG U 5000”
(where “5000” is the default unit configuration when a
new controller or software is loaded).
NOTE: If the Unit Configuration has already been
set, the current number (YYYY format) will show
instead of “5000”. The Unit Configuration MUST
always be set first.
4.
Press the SELECT key to enter the load configuration dis-
play (left display flashes “CFG U”).
5.
If the correct unit configuration is not known, check the
setup decal in the control box for the correct Unit
Configuration number. Then press the UP or DOWN key
to scroll to the correct number (number appears in right
display).
6.
Press the ENTER key to load the configuration number
selected. The display will briefly show “CFG U LOAD”
and then show the new CFG U setting in the right display.
7.
Press the DOWN key until display shows “CFG C 0”
(where “0” is the default customer configuration when a
new controller or software is loaded; or the Unit
Configuration is reset).
NOTE: If the Customer Configuration has
already been set, the current number (ZZ format)
will show instead of “0”. The Unit Configuration
MUST always be set first. The Customer
Configuration MUST always be set after the Unit
Configuration has been set.
8.
Press the SELECT key to enter the load configuration dis-
play (left display flashes “CFG C”).
9.
If the correct customer configuration is not known, check
the setup decal in the control box for the correct Customer
Configuration number. Then press the UP or DOWN key
to scroll to the correct number (number appears in right
display).
10. Press the ENTER key to load the configuration number
selected. The display will briefly show “CFG C LOAD”
and then show the new CFG C setting in the right display.
NOTE: If a new controller or new software has
been installed, proceed immediately to “Setting
the Container Identification Number” below.
Setting the Container Identification Number
1.
From “CFG C ZZ” (where ZZ is your customer configu-
ration number) in the Guard menu, press the DOWN key
until the display shows “CNFIG <--->”.
2.
Press the SELECT key to move back to the Guard sub-
menu (display shows “MENU CNFIG”).
3.
Press the DOWN key until display shows “CID11 XXX”.
Digits in the right display then begin to scroll to the left as
the last two digits in the left display indicate the position
of the number that is being shown in the right display.
4.
Press the SELECT key to enter the load Container
Identification Number display. The left display shows
“CID11” while the 11th digit flashes in the right display.
a.
Press the UP or DOWN key to choose a letter (A to
Z), a number (0 to 9) or a blank space.
b.
When the desired character appears in the 11th posi-
tion, press the SELECT key to choose the next posi-
tion. The left display shows “CID10” while the 10th
digit flashes in the right display.
c.
Repeat steps a and b for each character until the
Container Identification Number is entered.