background image

This manual, Code 20120617 - Rev. 2 (03/17) comprises 16 pages.

2

ENGLISH

 

 

RANGE

MODEL

CODE

TBPS 200 KOMPACT

20119548

TBPS 300 KOMPACT

20119549

TBPS 430 KOMPACT

20119550

ACCESSORIES

For a complete list of accessories and details of their compati-

bility, refer to the Catalogue.

Dear heating engineer,

We would like to congratulate you on having recommended a 

T

 solar storage cylinder unit: a modern product 

that's capable of ensuring a high degree of reliability, efficien-

cy, quality and safety.

While your technical skills and knowledge will certainly be 

more than sufficient, this booklet contains all the information 

that we have deemed necessary for the device's correct and 

easy installation.

Thank you again, and keep up the good work,

Thermital

CONFORMITY

The 

T

 solar heaters comply with DIN 4753-3 and 

UNI EN 12897.

ENGLISH

CONTENTS

The following symbols are used in this manual:

CAUTION! =

 Identifies actions that require caution and 

adequate preparation.

STOP! =

 Identifies actions that you MUST NOT do.

This manual, Code

- Rev.

comprises

pages.

GENERAL INFORMATION                                           3

General Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . 3

Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Description of the appliance  . . . . . . . . . . . . . . . . . . . . . . . . 4

Safety and control devices. . . . . . . . . . . . . . . . . . . . . . . . . . 4

Identification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

System layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

INSTALLATION                                                             8

Unpacking the product  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Access to the solar station . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Place of installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Installation in older systems and systems requiring 

modernisation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Water quality requirements. . . . . . . . . . . . . . . . . . . . . . . . . . 8

Water connections  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Typical water system schematics. . . . . . . . . . . . . . . . . . . . 10

Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Electrical connections  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

System flushing  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

System filling cock  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Device cleaning and maintenance. . . . . . . . . . . . . . . . . . . 13

COMMISSIONING AND MAINTENANCE                  14

Interventions on the hydraulic system  . . . . . . . . . . . . . . . . 14

Recycling and disposal  . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

END USER                                                                 15

Start-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Temporary shutdown  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Preparing for extended periods of disuse  . . . . . . . . . . . . . 15

External maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Содержание TBPS KOMPACT Series

Страница 1: ...TBPS KOMPACT INSTALLATION AND MAINTENANCE MANUAL...

Страница 2: ...EN 12897 ENGLISH CONTENTS The following symbols are used in this manual b CAUTION Identifies actions that require caution and adequate preparation a STOP Identifies actions that you MUST NOT do This m...

Страница 3: ...t immediately Keep the product purchase documents to be presented to the T authorised Technical Assistance Centre to request a service call under warranty b Size the solar expansion tank so as to ensu...

Страница 4: ...Safety valve with trigger pressure set at 6 bar Solar Regulator for circulator management control Manages 9 system diagrams that can be selected Re fer to the specific manual for further details IDEN...

Страница 5: ...t in non return valve 2 Delivery Valve solar plant delivery with built in non re turn valve 3 Outlet temperature gauge 4 Return temperature gauge 5 Insulation 6 Solar controller 7 Display 8 Multidirec...

Страница 6: ...1 33 W K Energy class B B B PERFORMANCE RELATING TO INTEGRATION COIL Upper coil continuous efficiency ACS 10 45 C Vbu reference volume Coil delivery temperature 80 C T 20 C 16 1 23 36 kW 400 572 890 l...

Страница 7: ...ccumulation tank lower part 70 C 374 438 659 l 60 C 284 375 531 l 50 C 205 310 390 l DESCRIPTION SOLAR STATION TECHNICAL DATA Safety valve calibration pressure 6 bar Maximum operating temperature 110...

Страница 8: ...sions are recommended for a correct maintenance and access to the device b When installing the boiler allow sufficient space around it to access all safety and control devices and to permit easy maint...

Страница 9: ...y diameter length of magnesium anode 1 33 450 1 33 450 1 33 520 mm DF Flange internal diameter 130 130 130 mm A 1120 1420 1270 mm B 171 171 208 mm C 403 393 427 mm D M8 threaded inserts for grounding...

Страница 10: ...ve an omnipolar magneto thermal circuit breaker and a disconnecting switch compliant with the prevail ing standards of the installation country respect the polarity of the L1 Phase N Neutral con necti...

Страница 11: ...robe cable together with mains power cables and or AC cables Absolutely avoid routing cables close to strong mag netic fields Avoid any cable jointing as much as possible solder and duly insulate any...

Страница 12: ...on valve VR counter clockwise Close taps A and B b During system flushing pay attention to water coming out of the taps as vapour could be released with risk of burns or scalds Use suitable personal p...

Страница 13: ...air bubbles have been eliminated Close the manual bleed valve and any vent valves opened previously Turn handle on valve VR counter clockwise Temporarily raise the pressure in the system to 4 bar Star...

Страница 14: ...d E Move away any wiring and electric devices below to protect them against any leakage of heat transfer fluid Close valves VR and VM by turning handle clock wise by 90 Open taps A and B and drain the...

Страница 15: ...supplied with the product End user TEMPORARY SHUTDOWN To reduce to the environmental impact and save energy in case of brief absences week ends short trips etc and with external temperatures above 0 C...

Страница 16: ...35017 Piombino Dese PD www thermital it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore l...

Отзывы: