GENERAL INFORMATION

GENERAL INFORMATION

GENERAL SAFETY INFORMATION

Check that the product is complete, undamaged and as 

ordered as soon as you receive it. Report any discrepan-

cies or damage to the 

T

 dealer who sold it.

This product must be installed by a legally qualified heat-

ing engineer. On completion of the installation, the install-

er must issue the owner with a declaration of conformity 

confirming that the installation has been completed to 

the highest standards in compliance with the instructions 

provided by 

T

 in this instruction manual, and 

that it conforms to all applicable laws and standards.

This product must only be used for the purpose for which 

it is designed and made, as specified by 

T

T

 declines all responsibility, contractual or 

other, for damage to property or injury to persons or ani-

mals caused by improper installation, adjustment, main-

tenance or use.

The product must be serviced at least once a year. Servic-

ing must be arranged in advance with the 

T

 

Technical Assistance Centre.

All servicing and repairs must be performed by a quali-

fied heating engineer.

If water leaks from the storage cylinder, turn off the water 

supply and contact 

T

’s Technical Assistance 

Centre or a qualified heating engineer immediately.

If the product is not going to be used for an extended 

period of time, contact the manufacturer’s Technical As-

sistance Centre to have at least the following operations 

performed:

- Close the shut-off cocks for the domestic hot water cir-

cuit

- Shut down the boiler connected to the storage cylinder 

as instructed in its own manual

- Switch the storage cylinder OFF at the control panel (if 

fitted) and at the mains power switch

- Drain the central heating circuit and domestic hot water 

circuit if there is any risk of freezing.

This instruction manual is an integral part of the prod-

uct. It must be kept safe and must ALWAYS accompany 

the product, even if it is sold to another owner or trans-

ferred to another user or to another installation. If you 

lose this manual, order a replacement immediately. Keep 

the product purchase documents to be presented to the 

T

 authorised Technical Assistance Centre to 

request a service call under warranty.

Size the solar expansion tank so as to ensure complete 

absorption of the expansion of the fluid contained within 

the system, with reference to the prevailing regulations 

on the matter. In particular, consider fluid characteris-

tics, considerable fluctuation of service temperature and 

vapour that might be generated during solar collector 

stagnation stage. Proper size of expansion tank ensures 

setting off of all volume changes of the heat transfer fluid, 

avoiding excessive pressure increase. Limited pressure 

changes avoid reaching safety valve opening pressure 

and the consequent fluid drainage.

PRECAUTIONS

The operation of any appliance that uses electrical power de-

mands that a number of fundamental safety precautions be 

respected. In particular:

Never attempt to install the system without using suitable 

personal protection equipment and without following all 

applicable occupational safety standards.

It is forbidden to touch the device while barefoot or with 

wet or moist body parts.

It is forbidden to perform any technical or cleaning op-

erations before having disconnected the device from its 

electrical power supply, by setting the system's main 

switch to "off".

It is forbidden to pull, detach, or twist the electrical ca-

bles protruding from the device, even if it is disconnect-

ed from its electrical power supply.

Do not expose the storage cylinder to the elements. It is 

not designed for use outdoors.

If solar plant pressure decreases, it is forbidden to top 

up with only water as there is a danger of freezing and 

overheating.

Do not use connections or safety devices or fittings (ex-

pansion vessels, pipes, insulation) that are not specifi-

cally designed and tested for use in solar water heating 

systems.

Do not allow children or infirm persons to operate the 

system unsupervised.

Do not dispose of packaging material into the environ-

ment, or leave it within the reach of children, since it can 

become a potential hazard. Dispose of packaging mate-

rial in compliance with applicable legislation.

It is forbidden to use the pipes for handling.

General information

Содержание TBPS KOMPACT Series

Страница 1: ...TBPS KOMPACT INSTALLATION AND MAINTENANCE MANUAL...

Страница 2: ...EN 12897 ENGLISH CONTENTS The following symbols are used in this manual b CAUTION Identifies actions that require caution and adequate preparation a STOP Identifies actions that you MUST NOT do This m...

Страница 3: ...t immediately Keep the product purchase documents to be presented to the T authorised Technical Assistance Centre to request a service call under warranty b Size the solar expansion tank so as to ensu...

Страница 4: ...Safety valve with trigger pressure set at 6 bar Solar Regulator for circulator management control Manages 9 system diagrams that can be selected Re fer to the specific manual for further details IDEN...

Страница 5: ...t in non return valve 2 Delivery Valve solar plant delivery with built in non re turn valve 3 Outlet temperature gauge 4 Return temperature gauge 5 Insulation 6 Solar controller 7 Display 8 Multidirec...

Страница 6: ...1 33 W K Energy class B B B PERFORMANCE RELATING TO INTEGRATION COIL Upper coil continuous efficiency ACS 10 45 C Vbu reference volume Coil delivery temperature 80 C T 20 C 16 1 23 36 kW 400 572 890 l...

Страница 7: ...ccumulation tank lower part 70 C 374 438 659 l 60 C 284 375 531 l 50 C 205 310 390 l DESCRIPTION SOLAR STATION TECHNICAL DATA Safety valve calibration pressure 6 bar Maximum operating temperature 110...

Страница 8: ...sions are recommended for a correct maintenance and access to the device b When installing the boiler allow sufficient space around it to access all safety and control devices and to permit easy maint...

Страница 9: ...y diameter length of magnesium anode 1 33 450 1 33 450 1 33 520 mm DF Flange internal diameter 130 130 130 mm A 1120 1420 1270 mm B 171 171 208 mm C 403 393 427 mm D M8 threaded inserts for grounding...

Страница 10: ...ve an omnipolar magneto thermal circuit breaker and a disconnecting switch compliant with the prevail ing standards of the installation country respect the polarity of the L1 Phase N Neutral con necti...

Страница 11: ...robe cable together with mains power cables and or AC cables Absolutely avoid routing cables close to strong mag netic fields Avoid any cable jointing as much as possible solder and duly insulate any...

Страница 12: ...on valve VR counter clockwise Close taps A and B b During system flushing pay attention to water coming out of the taps as vapour could be released with risk of burns or scalds Use suitable personal p...

Страница 13: ...air bubbles have been eliminated Close the manual bleed valve and any vent valves opened previously Turn handle on valve VR counter clockwise Temporarily raise the pressure in the system to 4 bar Star...

Страница 14: ...d E Move away any wiring and electric devices below to protect them against any leakage of heat transfer fluid Close valves VR and VM by turning handle clock wise by 90 Open taps A and B and drain the...

Страница 15: ...supplied with the product End user TEMPORARY SHUTDOWN To reduce to the environmental impact and save energy in case of brief absences week ends short trips etc and with external temperatures above 0 C...

Страница 16: ...35017 Piombino Dese PD www thermital it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore l...

Отзывы: