GENERAL INFORMATION
DESCRIPTION OF THE APPLIANCE
T
TBPS KOMPACT
double-coil solar boilers, with
pre-fitted solar station, are available in three different mod-
els, can be integrated in solar systems for the production of
domestic hot water and can be easily used in solar systems
where
T
boilers or heating groups serve as an in-
tegration.
The most important technical features of these solar storage
cylinders are:
- the accurate study of tank and coil geometry
- internal glazing, bacteriologically inert, to ensure the
max. hygiene of treated water, reduce limescale depos-
its and make cleaning operations easier
- insulation made of expanded polyurethane free from
CFC (chlorofluorocarbons)
- a flange for easy cleaning and maintenance of the an-
ti-corrosion magnesium anode
- solar station enclosed in an insulating casing in PPE
(Polypropylene foam), used also for solar system wash-
ing, filling and emptying as well as for circulator removal
The main components of the solar station are:
- high-efficiency circulator with variable speed (already
hard-wired)
- solar regulator (already hard-wired), as indicated in
paragraph "Safety and control devices"
- shut-off valves as non-return valves
- thermometers
- pressure gauge
- fitting for connection to a solar expansion tank
- suitable safety device, as indicated in paragraph "Safe-
ty and control devices"
SAFETY AND CONTROL DEVICES
Equipment safety and setting are achieved thanks to:
- Safety valve with trigger pressure set at 6 bar;
- Solar Regulator for circulator management/control.
Manages 9 system diagrams that can be selected. Re-
fer to the specific manual for further details.
IDENTIFICATION
The
T
TBPS KOMPACT
solar heaters can be iden-
tified by:
Data plate
This lists the technical specifications and performance of
the product.
RIELLO S.p.A.
Via Ing.Pilade Riello 7
37045 Legnago (VR) - ITALY
SOLARBOILER
Modell
Herstell. Nr.
Artikel Nr.
Baujahr
Maximaler Boilerbetriebsdruck
Anschlussspannung
bar
V-Hz
Boilerfassungvermögen
l
T067595ED02
ERDUNG OBLIGATORISCH - OBLIGATORY GROUND CONNECTION
W
Elektrischer Leistung
m
2
m
2
Leistungsaufnahme obere Rohrschlange
kW
Erzeugung von Brauchwasser
l/1'
[Primärkreislauftemperatur T=80°C]
SOLAR STORAGE CYLINDER
Model
Serial number
Code
Year
Power absorbed by top coil (T° primary 80°C)
Domestic Hot Water production - top coil
Maximum working pressure of storage cylinder
Storage cylinder capacity
Electrical consumption
Power supply
obere Rohrschlange[ 35°C]
∆T
Austauschoberfläche obere Rohrschlange
Top coil heat exchange surface area
Austauschoberfläche untere Rohrschlange
Bottom coil heat exchange surface area
Austauschoberfläche untere
Rohrschlange
Bottom coil heat exch. surf. area
Serial number
Model
kW
Power absorbed by top coil
Herstell. Nr.
Leistungsaufnahme obere
Rohrschlange
Modell
RIELLO S.p.A.
Via Ing.Pilade Riello 7
37045 Legnago (VR) - ITALY
m
2
Serial number plate
This specifies the serial number and model.
b
If these plates or any other means of clearly identify-
ing the product are defaced, removed or lost, proper
installation and servicing may be rendered difficult.