6
ENGLISH
GENERAL INFORMATION
GENERAL INFORMATION
TECHNICAL SPECIFICATIONS
DESCRIPTION
TBPS KOMPACT
200
300
430
Type of storage cylinder
Verticale,Vetrificato
Heat exchanger layout
Verticale a sezione ellittica
Storage cylinder capacity
208
301
442
l
Useful non-solar volume (Vbu)*
68
117
182
l
Solar usable volume (Vsol)**
140
184
260
l
Diameter of storage cylinder with insulation
604
604
755
mm
Diameter of storage cylinder without insulation
-
-
-
mm
Height with insulation
1338
1838
1644
mm
Height without insulation
-
-
-
mm
Insulation thickness
50
50
50
mm
Total net weight
86
108
131
kg
Quantity/diameter/length of magnesium anode
1/33/450
1/33/450
1/33/520
mm
Flange internal diameter
130
130
130
mm
Diameter/length of sensor sockets
18/180
18/180
18/180
mm
Top coil water capacity
3,4
4,5
6,0
l
Top coil heat exchange surface area
0,7
0,8
1,0
m
2
Bottom coil water capacity
3,4
5,1
7,5
l
Bottom coil heat exchange surface area
0,7
1,0
1,4
m
2
Maximum operating pressure of storage cylinder
10
bar
Maximum operating pressure of coils
10
bar
Maximum operating temperature
99
°C
Discharges according to EN 12897:2006 ∆T=45 °C
(ambient 20°C and storage at 65°C)
62
69
60
W
Discharges according to UNI 11300
1,38
1,53
1,33
W/K
Energy class
B
B
B
PERFORMANCE RELATING TO INTEGRATION COIL
Upper coil continuous efficiency (ACS 10-45°C) (Vbu reference volume)
Coil delivery temperature
80°C
∆T 20°C
16,1
23
36
kW
400
572
890
l/h
70°C
∆T 20°C
10,3
17
26
kW
247
425
655
l/h
60°C
∆T 20°C
6,5
11
16
kW
160
277
416
l/h
50°C
∆T 20°C
2,4
5
7
kW
57
130
170
l/h
Set-up time required to heat the heater to 60°C, referred to the integration coil probe, to the different upper coil inlet
temperatures with a coil outlet/inlet delta (∆) of 20°C (Vbu reference volume)
Upper coil delivery temperature
80°C
∆T 20°C
25
27
27
min
70°C
∆T 20°C
33
34
29
min
60°C
∆T 20°C
66
65
66
min
NL thermal efficiency coefficient according to DIN 4708. The NL index, referred to the integration exchanger, indicates a
number of apartments having 3.5 people that can be fully supplied, with a 140 l bathtub and two other drawing points.
Upper coil delivery temperature
80°C
1,12
1,64
2,42
70°C
0,86
1,34
1,92
60°C
0,65
1,04
1,4
Vbu (*)
The non-solar usable volume indicates the quantity of water (in litres) heated directly by the thermal integration coil. It
is calculated as the volume between the upper part of the heater and the lower part of the thermal integration element
(integration coil lower turn).
Vsol (**)
The usable solar volume indicates the quantity of water (in litres) heated directly by the solar coil (placed in the lower
part of the heater) minus the non-solar volume (Vbu).