1-26
Themis Computer
RES-XR4-3U Installation Manual
Version 1.3
1.5.1.2 Output Voltage
The RES-XR4-3U power supply provides output voltages that are split between
+3.3V, +5V, +5Vsb, +12V, and -12V rails.
1.5.2
Environmental
1.5.2.1 Shock
The RES-XR4-3U is designed to survive an elevated shock environment. All struc-
tural components are welded together, enabling the system to survive a maximum
3-axis shock load of 30 g at 25-ms duration.
1.5.2.2 Electrostatic Discharge
The RES-XR4-3U is designed to tolerate electrostatic pulses up to 15 kilovolts (KV)
with no impact on system operation.
1.5.2.3 Noise
The RES-XR4-3U conforms to the 54-db noise specification. It is possible to
achieve further noise reduction by installing a sound baffle on both the front and rear
of the RES-XR4-3U chassis (See
page 1-28). Call your Themis representative for additional information.