B-1
Themis Computer
B
Rack-Mount Slide Installation
An
optional
set of two rack-mount slides (left side and right side) is available for all
RES-XR4 systems, and should be ordered at the time of purchase. The RES-XR4-
3U chassis contains six threaded screw holes on each side to accommodate #8-32
size screws (included with the rack-mount slide kit); steel slides require four mount-
ing holes, and aluminum slides require three mounting holes (see
).
Figure B-1.
Screw Locations for Rack-Mount Slides
440.8
339.2
250.6
202.4
149.1
85.6
37.6
Front
0
424.9
24.9
Screw Hole Size = #8-32
Legend
Mounting
Bezel
Cover
Bracket
Note:
All dimensions are given in millimeters (mm), and measured from the baseline “0” of the drawing
Appendix