![Texas Instruments TMS470R1x Скачать руководство пользователя страница 94](http://html.mh-extra.com/html/texas-instruments/tms470r1x/tms470r1x_reference-manual_1097091094.webp)
Control Registers and RAM
86
Bit 30
RELOAD.
Pre-load tick counter.
RELOAD is a set-only bit, i.e. writing a “1” to it automatically reloads the tick
counter with the value stored in TICKICNT. Reading RELOAD always returns
a “0”.
Note:
When the tick counter is reloaded by the RELOAD bit, the trigger signal is not
toggled.
Bit 29:28
CLKCTRL.
Tick counter clock source control.
CLKCTRL[1:0] defines the clock source that is used to clock the MibSPI
internal tick counter.
Bits 27:16
Reserved
Bits 15:0
TICKVALUE.
Initial value for tick counter.
TICKVALUE stores the initial value for the tick counter. The tick counter is
loaded with TICKVALUE every time an under-flow condition occurs and every
time the PRELOAD flag is set by the host.
CLKCTRL[1:0]
Description
00b
SPICLK of Data word format 0 is selected as clock source of tick counter
01b
SPICLK of Data word format 1 is selected as clock source of tick counter
10b
SPICLK of Data word format 2 is selected as clock source of tick counter
11b
SPICLK of Data word format 3 is selected as clock source of tick counter
Содержание TMS470R1x