SUB ACC,loc16 << #0...16
6-334
Repeat
If the operation is repeatable, then the instruction will be executed N+1
times. The state of the Z, N, C flags will reflect the final result. The V flag will
be set if an intermediate overflow occurs. The OVC flag will count
intermediate overflows, if overflow mode is disabled. If the operation is not
repeatable, the instruction will execute only once.
Example
; Calculate signed value: ACC = (VarA << 10) − (VarB << 6);
SETC SXM
; Turn sign extension mode on
MOV ACC,@VarA << #10
; Load ACC with VarA left shifted by 10
SUB ACC,@VarB << #6
; Subtract VarB left shifted by 6 to ACC0
Содержание TMS320C28x
Страница 30: ...1 12...
Страница 80: ...This page intentionally left blank 2 50 This page intentionally left blank...
Страница 269: ...IN loc16 PA 6 112 MOV AL 0 AL 0 UOUT IORegC AL IOspace IORegC AL 10...
Страница 308: ...MAXCUL P loc32 6 151 Saturate MOVL Var64 2 ACC Store result into Var64 MOVL Var64 P...
Страница 509: ...SUBL ACC P PM 6 352 SUBL ACC P PM ACC S B 11 M X 4 MOVH Y ACC 5 Store Q15 result into Y...