11.2. Burst Settings and limits
11.2.1. Configuration
In the configuration menu the user set the following parameters:
-
Signal trigger
for start the test or step is indicated by the blinking Start button.
-
Trigger out signal
at the BNC plug on generator front side
- Behavior of the
EUT Monitor 1
, BNC plug at the rear side
Iterations
The voltage Iteration tests the parameters changes after each step/cycle as shown in the figure below.
Example with voltage iteration that illustrate trigger out for cycle and step
11.2.1.1.
Signal Trigger
For start/continue the test press Start button:
-
Automatic
Test starts automatic after START
- At
Start
Press START again after running the test
- Each
Step
every burst parameter changing. (voltage, polarity)
11.2.1.2.
Trigger OUT
The trigger out signal is a programmable 5V edge signal located at the front side BNC Trigger plug. This
signal is for trigger other devices like oscilloscopes or other devices.