Make sure E-TES SD unit power switch is in the OFF position, and then connect the receptacle end of the
GFCI cords to E-TES SD unit. Reset GFCI on both power cords. Push TEST button to test GFCI and if
RESET button pops out and the red FAULT Indicator light turns on, push RESET button back in and
proceed with set-up. If RESET button does not pop out when TEST button is pushed, replace cord or contact
your nearest service center for advice or assistance. When operating properly the red FAULT light on the GFCI
unit will be OFF. Once the unit is plugged in and reset, if there is a power outage the GFCI will reset
automatically. If tripped by a ground fault incident, the GFCI must be manually reset
6)
Turn E-TES SD unit power switch to the ON position. Observe Dual Circuit indicator light next to rocker
switch. If green light is ON, cords are on separate circuits and you can proceed with set-up. If light is OFF both
cords are on the same circuit and one cord must be moved. When cords are on separate circuits and green Dual
Circuit indicator light is on proceed with set-up.
If Cord #1 is connected properly and supplying power to the Cord #1 connector, the LED display,
POWER light and HEATING light will operate normally even if Cord #2 is disconnected or
connected to a dead outlet. The unit will still operate, but at only one half of its rated heat output.
CONNECT CORD
#1 HERE
CONNECT CORD
#2 HERE
DUAL CIRCUIT
INDICATOR LIGHT
Must be ON for proper
operation
E-TES SD POWER
SWITCH
E-TES SD 120VOLT LP SWITCH PLATE
RESET BUTTON
FAULT INDICATOR LIGHT
GFCI TEST BUTTON
GFCI MODULE