Air Flow Setup Screen:
This allows you to recalibrate the Air Pressure Sensor to maintain
proper air pressure sensor function for reliable heater operation.
Current Job Time Screen:
This shows the time the system has run since the switch was last
turned on.
Total System Time Screen:
This shows the total time the system has been run on all jobs.
Current Date and Time Screen
•
Press
DOWN
to return to Main Screen
•
Press
UP
to return to Total System Time Screen
Press
SELECT
to set the E-TES SD Date & Time
Clock.
HOUR will flash first. Use the
UP/DOWN
buttons
to change the HOUR setting. When correct, press
SELECT
to move to MINUTES, then SECONDS,
MONTH, DAY NUMBER & finally YEAR. Use
UP/DOWN
to change each setting and
SELECT
to move to next option. When correct, press
SELECT
to save setting
(The DAY will change as you change MONTH,
DAY NUMBER or YEAR.)
•
Press
DOWN
to move to Total System Time Screen
•
Press
UP
to return to Air Flow Setup Screen
•
Press
DOWN
to move to Date & Time Screen
•
Press
UP
to return to Current Job Time Screen
•
Press
DOWN
to move to the Current Job Time Screen.
•
Press
UP
to return to the Remote Setup Screen
Press
SELECT
to set the Air Pressure Sensor trigger point.
Follow the screen directions using the
DOWN
button to set
the levels with the air mover OFF & ON.
1.
First turn the air mover OFF. When the fan is off and
the number stops changing, press
DOWN
.
This is the Off Set Point.
(Shown as 000 in this example)
2.
Then turn the air mover ON at low speed. Press
DOWN
as soon as the fan on number is about 15-25
points higher than the Off Set Point. This is the ON
Set Point. (Shown as 022 in this example)
3.
The Air Flow Trigger point is now set. The Air Flow
Trigger is approximately half way between the Off Set
Point and the On Set Point.
(Shown as 012 in this example)