MAINTENANCE
38
Tennant T300e/T300 (03- 2015)
Before Charging
After Charging
FIG. 113
NOTE: Make sure the battery caps are in place while
charging. There may be a sulfur smell after charging
batteries. This is normal.
CHECKING CONNECTIONS / CLEANING
After every 200 hours of use, check for loose battery
connections and clean the surface of the batteries,
including terminals and cable clamps to prevent battery
corrosion. Use a scrub brush with a strong mixture of
baking soda and water (Figure 114). Do not remove
battery caps when cleaning batteries.
FIG. 114
CHARGING BATTERIES
The charging instructions in this manual are intended
for the battery charger supplied with your machine. The
use of other battery chargers that are not supplied and
approved by Tennant are prohibited.
If your machine is equipped with an off-board battery
charger refer to the charger’s owners manual for
operating instructions. Contact distributor or Tennant
for battery charger recommendations if machine is not
equipped with charger.
FOR SAFETY: The use of incompatible battery
chargers may damage battery packs and
potentially cause a fire hazard.
IMPORTANT NOTICE:
The battery charger is set to
charge the battery type supplied with your machine. If
you choose to change to a different battery type or
capacity (i.e. flooded (wet) lead-acid,
maintenance-free, sealed, AGM batteries, etc.), the
charger’s charging profile must be changed to prevent
battery damage. See BATTERY CHARGER
SETTINGS.
1. Transport the machine to a well-ventilated area.
WARNING: Batteries emit hydrogen gas.
Explosion or fire can result. Keep sparks and open
flame away when charging.
2. Park the machine on a flat, dry surface, turn off
machine and remove key.
FOR SAFETY: When servicing batteries, stop on
level surface, turn off machine, remove key and set
parking brake if equipped.
3. If the machine is equipped with flooded (wet) lead-
acid batteries check the battery electrolyte level
weekly before charging.
See FLOODED (WET)
LEAD-ACID BATTERIES.
4. For models equipped with on-board chargers,
remove the charger’s power cord from the storage
hooks and plug power cord into a properly
grounded wall outlet (Figure 115).
FIG. 115
Содержание IRIS T300
Страница 49: ...SPECIFICATIONS Tennant T300e T300 03 2015 49 1095 mm 772 mm DUAL DISK MODEL 1314 mm 660 mm...
Страница 50: ...SPECIFICATIONS 50 Tennant T300e T300 03 2015 1095 mm 772 mm CYLINDRICAL BRUSH MODEL 1283 mm 635 mm...
Страница 51: ...SPECIFICATIONS Tennant T300e T300 03 2015 51 1095 mm 772 mm ORBITAL PAD MODEL 1245 mm 521 mm...
Страница 52: ...SPECIFICATIONS 52 Tennant T300e T300 03 2015...