MAINTENANCE
Tennant T300e/T300 (03- 2015)
37
BELTS
FOR SAFETY: Before leaving or servicing machine,
stop on level surface, turn off machine, remove key
and set parking brake if equipped.
Replace belts every 1250 hours. Contact trained
personnel for belt replacement (Figure 111).
Cylindrical Brush Drive Belt
Dual Disk Brush Drive Belt
FIG. 111
ORBITAL SCRUB HEAD ISOLATORS
FOR SAFETY: Before leaving or servicing machine,
stop on level surface, turn off machine, remove key
and set parking brake if equipped.
Replace the four lower vibration isolators every 500
hours. The lower isolators (hidden) are located
between the deck plate the driver plate. Contact trained
personnel for isolator replacement (Figure 112).
FIG. 112
BATTERIES
FOR SAFETY: Before servicing machine, stop on
level surface, turn off machine, remove key and set
parking brake if equipped.
The lifetime of the batteries depends on their proper
maintenance. To get the most life from the batteries;
S
Do not charge the batteries more than once a day
and only after running the machine for a minimum of
15 minutes.
S
Do not leave the batteries partially discharged for
long period of time.
S
Only charge the batteries in a well-ventilated area to
prevent gas build up. Charge batteries in areas with
ambient temperatures 27
_
C or less.
S
Allow the charger to complete charging the batteries
before re-using the machine.
S
Maintain the proper electrolyte levels of flooded (wet)
batteries by checking levels weekly.
Your machine is equipped with either flooded (wet)
lead-acid or maintenance-free batteries supplied by
Tennant.
FOR SAFETY: When servicing machine, keep all
metal objects off batteries. Avoid contact with
battery acid.
MAINTENANCE-FREE BATTERIES
Maintenance-free (Sealed AGM) batteries do not
require watering. Cleaning and other routine
maintenance is still required.
FLOODED (WET) LEAD-ACID BATTERIES
The flooded (wet) lead-acid batteries require routine
watering as described below. Check the battery
electrolyte level weekly.
The electrolyte level should be slightly above the
battery plates as shown before charging (Figure 113).
Add distilled water if low. DO NOT OVERFILL. The
electrolyte will expand and may overflow when
charging. After charging, distilled water can be added
up to about 3 mm below the sight tubes.
Содержание IRIS T300
Страница 49: ...SPECIFICATIONS Tennant T300e T300 03 2015 49 1095 mm 772 mm DUAL DISK MODEL 1314 mm 660 mm...
Страница 50: ...SPECIFICATIONS 50 Tennant T300e T300 03 2015 1095 mm 772 mm CYLINDRICAL BRUSH MODEL 1283 mm 635 mm...
Страница 51: ...SPECIFICATIONS Tennant T300e T300 03 2015 51 1095 mm 772 mm ORBITAL PAD MODEL 1245 mm 521 mm...
Страница 52: ...SPECIFICATIONS 52 Tennant T300e T300 03 2015...