OPERATION
20
Tennant T300e/T300 (03- 2015)
T300 WITH PRO-MEMBRANE CONTROL PANEL
(Actuated Down Pressure Model)
The control panel operation can be set up with lockout
functionality by using the supervisor controls feature.
This will prevent an operator from changing or saving
the Zone Settings. See SUPERVISOR CONTROLS
instructions at back of manual.
1. Turn the key to on ( I ) position to power up
machine.
Models equipped with the ec-H2O option - The
ecH2O system will automatically turn on at start up.
A blue ec-H2O icon will appear on the control panel
(Figure 43). This indicates that the ecH2O system
is turned on and ready for operation. To turn off the
ec-H2O system, press the ec-H2O switch located
below the key switch.
FIG. 43
2. Press the down pressure button to increase or
decrease the down pressure (Figure 44). The down
pressure indicator will display the pressure setting.
One LED = Low pressure, two LED’s = Medium
pressure, three LED’s = High pressure.
FIG. 44
3. Press the solution flow button to increase or
decrease the solution flow rate (Figure 45). The
solution flow indicator will display flow setting.
No LED = No flow, One LED = Low flow, two
LED’s = Medium flow, three LED’s = High flow.
FIG. 45
4. Models equipped with Severe Environment button
option - Press Severe Environment button one
time to dispense cleaning detergent for 30 seconds
(Figure 46). A green LED in the corner will blink
slowly when dispensing. During the last 5 seconds,
the LED will blink rapidly as an alert that the
dispensing is about to stop. For continuous
dispense, press and hold the button for 2 seconds
until LED turns solid green. Press button at
anytime to turn off.
The icon will blink blue when the severe
environment tank needs to be refilled.
NOTE: When the severe environment mode is
turned on, the down pressure and solution flow
settings automatically increase to the high setting.
When turned off, the settings revert back to the
original settings.
FIG. 46
5. Models equipped with Quiet-Mode option - Press
the Quiet-Mode button to reduce the vacuum motor
sound (Figure 47). A green LED in the corner will
turn on when mode is activated. Press button to
turn off.
NOTE: Water pickup will reduce slightly when
Quiet-Mode is activated.
FIG. 47
6. Press the Zone Setting numbers for quick
operation (Figure 48). The three preset zones are
factory configured with different solution flow rates
and down pressures.
FIG. 48
Содержание IRIS T300
Страница 49: ...SPECIFICATIONS Tennant T300e T300 03 2015 49 1095 mm 772 mm DUAL DISK MODEL 1314 mm 660 mm...
Страница 50: ...SPECIFICATIONS 50 Tennant T300e T300 03 2015 1095 mm 772 mm CYLINDRICAL BRUSH MODEL 1283 mm 635 mm...
Страница 51: ...SPECIFICATIONS Tennant T300e T300 03 2015 51 1095 mm 772 mm ORBITAL PAD MODEL 1245 mm 521 mm...
Страница 52: ...SPECIFICATIONS 52 Tennant T300e T300 03 2015...