2 Read carefully before use
2.1 Important information
WARNINGS!
The practice and the maintenance of the heat pump
KITA
Templari®, are subject to legal systems of the countries where it
is used. According to the quantity of cooling fluid it is necessary
to check e annotate the hermetic seal of the heat pump at
regular intervals resorting to a qualified staff.
•
During the transport it is possible to tilt the heat pump no
more than 45° (in each direction).
•
The safety for the transport has to be removed before of
the put in action.
•
The aspiration and unloading zone mustn’t be reduced or
covered.
•
Respect specific building regulations of each countries.
•
For the installation near the wall you have to consider degli
influences due to building physiscs factors. In the area of
unload of the fan there must be no windows or doors.
•
With the installation near the wall the air flow in the
aspiration and unloading zone can give a greater deposit
of impurity. The colder outside air has to go out so to not
increase the heat loss of bordering heated rooms.
•
the dirt trap, not included but supplied on demand of
the customer, must be assembly on the heating return
upstream of the heat pump.
•
The istallation in niches or inner courtyards isn’t allowed,
because the cooled air accumulates on the ground and in
case of prolonged operation it would be aspirated back by
the heat pump.
•
The freezing limit can change following the climatic region.
Respect the regulations in force for the countries concerned.
•
Respect the right-handed rotation field: in case of incorrect
wiring the start of the heat pump is hindered. The programmer
of the heat pump shows the relevant warning indication (to
correct the wiring).
•
The operation of the heat pump with too low temperature
system can cause its total block. After a prolonged power cut
you have to use the method of put in action described below.
•
Clean at regular intervals the dirt trap.
•
Before opening the device cut off power to all the electrical
circuits.
•
Works on the heat pump can be done only by authorized and
competent people of the customer care.
2.2 Proper use
The heat pump
KITA Templari® is homologate just for the use
providede by the manufacturer. A different use moving away
from the provided one is considered not-compliant. The proper
use also includes the respect of the information included in
the relevant informative. It’s forbidden to make changes or
transformations to the device.
2.3 Rules and law provided
This heat pump is destined, according to the article 1, chapter 2
k) of Directive CE 2006/42/CE (Machines Directive), to the use in
domestic and for this reason it is subject to the requirements of
the Directive 2006/95/CE (Low power Directive). In this way it
is arranged to be used by inexperienced people to heat shops,
offices and similar work environments, farms, hotels, small
hotels and similar or other residential buildings.
In the planning and realization of the heat pump all the
correspondant CE directives and DIN and VDE regulations are be
respected (see Dichiarazione di conformità CE).
The electrical connection of the heat pump
KITA Templari® has to
be made following the current rules VDE, EN e CEI. Furthermore
the connection conditions of network operators of supply have
to be respected.
Concerning the heating system connection you have to follow
current provisions.
People, in particular kids, who on the base of physical, sensory
or mental abilities, or for inexperience or incompetence aren’t
able to use the device in safety, must’t use the device without a
responsible person’s supervision or guide.
Make sure kids don’t play with the device.
2.4 Energy saving
Using the heat pump
KITA Templari® you contribute to the
respect of the environment. Condition for a energi saving
operation mode is the correct disposition of heat sources and of
the system for the utilization of thermal energy.
Very important for the effciency of a heat pump is to keep the
difference of temperature between the heating water and the
heat source as low as possible. For this reason we strongly
recommend an accurate sizing of the heat source and of the
heating system. A difference of temperature higher than a degree
Kelvin (a °C) causes an increase of energy consumption of 2,5 %
about. It is necessary to be careful, during the heating system
sizing, how special users are considered, as for example hot water
production, and and how they are sized for low temperatures. An
underfloor heating (surface heating) is the ideal to use a heat
pump thanks to flow temperatures (from 30 °C to 40 °C).
During the operation it is important that impurities aren’t
accumulated in the heat exchangers, because the make increase
the difference of temperature, worsening then the coefficient of
performance.
3 Intended use of the heat
pump
3.1 Fields of work and safety devices
The heat pump
KITA Templari® is enable to work at outdoor
temperature between -22°C (for the version S and M) and -32°C
(for the version L) and +46°C.
The machine allows following operations fields relating to the
temperatures of the water produced:
•
Heating: mimimum temperature 10°C, maximum
temperature 55°C
•
Production of domestic hot water: minimum temperature
35°C, maximum temperature 55°C
•
Cooling: minimum temperature 7°C, maximum
temperature 40°C.
The heat pump
KITA Templari® is equipped with a safety pressure
switch that stop the operation of the machine when a pressure