Version 3 - Two relès, to manage DHW and
auxiliary integration.
If you want to manage a 3-way valve for domestic management
and in the same time the ignition of an electrical resistance /
boiler, the terminal presents two relès: K1 for the management
of DHW and K3 for the auxiliary integration.
For standard connections make reference to the table mentioned
in version 1.
Here below is shown the table with the contacts for the
connection of relès K1 and K3.
K3
K1
L L L N
L N
1
2
4
3
1 3 5 7 9 11
2 4 6 8 10 12
B3 - Y3 - B7 -
B2 - B4 - B5 -
1
3
5
7
9
11
2
4
6
8
10
12
B2
Gnd
B4
GND
B5
+VDC
B3
GND
Y3
GND
B7
GND
L L L N
L N
1
2
4
3
1 3 5 7 9 11
2 4 6 8 10 12
B3 - Y3 - B7 -
B2 - B4 - B5 -
1
3
5
7
9
11
2
4
6
8
10
12
B2
Gnd
B4
GND
B5
+VDC
B3
GND
Y3
GND
B7
GND
Relè K1
MANAGEMENT DHW
117
Relè coil. To contact NO9 of the µPc
118
Relè coil.To Neutral of external unit.
121
Contact normally open (Na)
122
Contact normally close (Nc)
123
Common Contact ( C )
Relè K3
MANAGEMENT RESISTANCE / BOILER
119
Relè coil. To contact NO8 of the µPc
120
Relè coil.To Neutral of external unit.
124
Contact normally open (Na)
125
Contact normally close (Nc)
126
Common Contact ( C )
Connection 3-way valve Templari - de pala and integration
Phase open (BROWN)
Phase close (BLU)
14
12
11
Neutral (BLACK)
Earth (YELLOW - GREEN)
Earth
Neutral
Phase
3-WAY VALVE
DOMESTIC LINE
EXTERNAL UNIT RELÈ K1
Contact N/A
14
11
12
Common Contact
Contact N/C
INTEGRATION
CLEAN CONTACT
EXTERNAL UNIT
RELÈ K3
3 way:
Brown = Phase open
Black = Neutral
Blu = Phase close
Y/G = Earth
K1/K3
9.6 Terminal block wiring single-phase
models supply
L L L N
L N
1
2
4
3
1 3 5 7 9 11
2 4 6 8 10 12
B3 - Y3 - B7 -
B2 - B4 - B5 -
1
3
5
7
9
11
2
4
6
8
10
12
B2
Gnd
B4
GND
B5
+VDC
B3
GND
Y3
GND
B7
GND
L L L N
L N
1
2
4
3
1 3 5 7 9 11
2 4 6 8 10 12
B3 - Y3 - B7 -
B2 - B4 - B5 -
1
3
5
7
9
11
2
4
6
8
10
12
B2
Gnd
B4
GND
B5
+VDC
B3
GND
Y3
GND
B7
GND
L L L N
L N
1
2
4
3
1 3 5 7 9 11
2 4 6 8 10 12
B3 - Y3 - B7 -
B2 - B4 - B5 -
1
3
5
7
9
11
2
4
6
8
10
12
B2
Gnd
B4
GND
B5
+VDC
B3
GND
Y3
GND
B7
GND
1
Supply: power terminal block
2
Inverter fuses 32 A
3
Auxiliary fuses 4 A
4
Sensor terminal block (the simbol - indicates GND)