7.10 Scheme 6: Cooling/heating system, with buffer.
In this configuration, you MUST always keep open at least 25% of the collector area.
The bypass valve must have a broad scope to ensure the proper operation of the heat pump when the radiant system allows little
water passage.
PROBE
B7
PROBE
B4
GA
GA
RD
MA
UE
USER INTERFACE
COLLECTOR
FY
VE
RD
PROBE B2
SIGNAL CABLES
OUT
IN
GA
MA
RD
VE
FY
UE
An�-vibra�on joint
Manometer
Drin tap
Expansion vessel
Y-filter
External unit
ATTENZIONE!
Build a plant with buffer on outlet pipe is the least effective method and, although you can use it, we do not recommend its use.
The buffer used on outlet pipe must always comply with a minimum quantity of liters according to the heat pump KITA used:
KITA S 200 Liters, KITA M 300 Liters, KITA L 500 Liters