![Templari KITA ACQUA Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/templari/kita-acqua/kita-acqua_installation-and-maintenance-manual_1085665026.webp)
26
www.templari.com
9.3 Supply
Connect the supply of the machine to the internal terminal block
according to the scheme shown below. The cable routing occurs
throught the special holes as shown in the previous schemes.
APPROXIMATE section of cables and internal protection:
WARNINGS!
The cable section of supply has to be considered approximate
and relevant to the last section of the line towards the machine
that has to be as short as possible. The external protections, the
laying and the section of the cables of the supply line mentioned
have to be dimensioned and made by an authorized staff and
according to technical standards of the relevant national rules.
Power cables indication
• L42
• L66
• L33
• M Plus
• M3Phase
• S3Phase Plus
• S3Phase
• M
• S Plus
• S
Supply
400 Vca - 50 Hz
400 Vca - 50 Hz
230 Vca - 50 Hz
230 Vca - 50 Hz
Cable*
5x6 mmq
5x4 mmq
3x6 mmq
3x4 mmq
Protections of
line 400 Vca
3 fuses -
10.3x38-32A
3 fuses -
10.3x38-32A
Protections of
line 230 Vca
2 fuses-
10.3x38-32A
2 fuses- 10.3x38-
32A
Protections of
secondary line
230
4 fuses - 5x20-
4A
4 fuses - 5x20-
4A
2 fuses - 5x20-
4A
2 fuses - 5x20-
4A
* Maximum 5 meters up to the first branch. If the cable is longer increase adequately the section according to regulations.