![Tempest Tacit 8 56.050L Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/tempest/tacit-8-56-050l/tacit-8-56-050l_user-manual_1085640044.webp)
Tacit 8 User Manual
44
DMX level 81-100 No change to relay status
SET DATA RESPONSE
DMX Response sets a delay time before DMX Control Mode settings are acted on. Setting a response delay of a few
seconds would prevent unintended fixture relay state changes in the event of a short accidental change in DMX
level.
NOTE: from firmware revision 0.00.100, DEC holds last valid DMX level if DMX is interrupted.
Response Delay Values are:
No Delay (default), 1, 2, 5, 10, 15, 20, 30, 60 seconds.
Set Temp Units
Choose to display temperature values in Celsius or Fahrenheit (default Celsius)
Note that temperature settings must be entered in Celsius.
Set Temp Ranges
Set three temperature trigger points for Bottom, Top and Trip temperatures, in °C.
SET TEMP LOWER (minimum temperature to be maintained)
(default 10°C, permissible range 0-10°C).
SET TEMP UPPER (maximum desired daytime temperature)
(default 45°C, permissible range 25-50°C).
Zen and Tacit enclosures:
Adjust the UPPER TEMPERATURE setting as desired to balance cooling versus fan speed:
Lower Temperature = faster fan speed = more fan noise
Higher temperature = slower fan speed = less fan noise
SET TEMP TRIP (temperature at which load will be isolated
–
see note)
(default 60°C, permissible range 55-70°C).
Note: A thermal emergency is when enclosure ventilation fails with the lamp on, in which case the temperature will
rise very quickly. To avoid nuisance tripping we recommend setting a higher Trip temperature, 60°C or above.
Set Max Humidity (outdoor Enclosures only)
Sets highest desired Relative Humidity: Default 85%, permissible range 80-90%.
Note that, when the projector/luminaire lamp is OFF, the enclosure heaters will switch on to raise the temperature
and lower the risk of condensation. We recommend setting the highest Max Humidity that works in your location, to
avoid unnecessary heater use.
Содержание Tacit 8 56.050L
Страница 6: ...Tacit 8 User Manual 6 Approvals China...
Страница 10: ...Tacit 8 User Manual 10 Remote Fan Module Dimensions and Mounting Tacit 050 150...
Страница 11: ...Tacit 8 User Manual 11 Remote Fan Module Dimensions and Mounting Tacit 210 and Up...
Страница 38: ...Tacit 8 User Manual 38 Fan Transition Board Remote Fan Fuse 6 3A slow blow Spare fuse...