RS485 (DMX/RDM) Cable Terminations
Loop a shielded twisted pair cable (eg Belden 9841, though
many people now use a CAT5e cable) from the
control/monitoring point, around all enclosures.
Maximum total cable length is 1,200M (4,000ft). For longer
runs and wildly distributed systems, use a DMX/RDM
splitter (make sure that it supports RDM) and multiple
cable runs.
Use the termination switch to terminate each RS485 cable
run at the last enclosure on each run.
RS485 Line
Termination
(LT) Switch:
TERMINATED
Data + Data - Common Data + Data - Common
DATA OUT DATA IN
DEC4 System Control
Board, with three typical
Daughter Boards:
1.
AC Fan Controller
2.
Ethernet Bridge
3.
RS485 Comms
Terminal Screw Torque Setting 0.5Nm/4.5in-lb