background image

 

 

 

 

 

Tacit 8 User Manual 

 

61 

 

Projector Mounting Tacit 210 and up 

 Portrait/8 rigging points 

This mounting style is for projectors with a rigging point at 
each corner of the projector chassis (mainly larger Christie 
projectors). The portrait mounting kit allows horizontal 
mounting and tilt up to 6 degrees up or down. 

IMPORTANT: 

Projectors with air inlets on the side of the projector 
chassis: The inlet side MUST face down, for optimal airflow. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Christie Crimson with portrait 
mounting kit and maximum 
downward tilt. For upward tilt, 
reverse the mount, with the 
triangular plate at the front. 
 

 

Approximate Tilt Angles: 
5

° 

4

°

 

3

°

 

2

° 

1

° 

0

°

 

 
 

Triangular Angle Plate 
 
M8 Nut 
 
M8 Washer 
 
M12 Projector Bolt 
 
Portrait Mount Bar 
 
M8 Washer 
 
M8 Nut 
 
 
M8 Carriage Bolt 

Pivot Plate 
 
M12 Projector Bolt 
 
M8 Washer 
 
M8 Nut 
 
M8 Carriage Bolt 

Side air inlets? 

Make sure they face DOWN 

 

Содержание Tacit 8 56.050L

Страница 1: ...Tacit 8 User Manual 1 User Manual Tacit 8 Revision 8 4 November 2021 Tempest Lighting Inc IMPORTANT For Tacit Enclosures manufactured after July 2019...

Страница 2: ...cess Clearance 13 Enclosure Tilt 13 Inlet Air Duct 14 Exhaust Air Duct 14 Installing Ducts and Fan Module 15 Fan Modules 15 Fan Wiring 16 Wiring the Enclosure 17 Power Wiring 17 SAFETY NOTICE 17 Elect...

Страница 3: ...closure Control 35 Schematic PWM 35 DEC4 Main Functions 36 Firmware Revision 36 Factory Settings Data Modes 36 Hardware Indicators Fuses 37 DEC System Control Board 37 Fan Transition Board 38 Operatin...

Страница 4: ...cape Feet up 60 Projector Mounting Tacit 210 and up Portrait 8 rigging points 60 Projector Mounting Tacit 210 and up Portrait 4 rigging points 62 Projector specific Mounting 63 Christie D4K 40 RGB Lan...

Страница 5: ...ltage Directive 2014 35 EU Test Report 60065 6500 01 14 Electromagnetic Compatibility Directive 2014 30 EU Test Report 61000 6500 03 14 and further conforms with the following EU Harmonized Standards...

Страница 6: ...Tacit 8 User Manual 6 Approvals China...

Страница 7: ...Lifting some enclosures and the equipment inside them may be heavy Use properly rated lifting equipment where appropriate and never attempt to carry out work with fewer than the number of workers need...

Страница 8: ...1 245 23 584 257 117 56 305L 51 1 295 34 864 24 610 49 1 245 32 813 205 93 56 305P 51 1 295 25 635 36 914 49 1 245 23 584 226 103 56 310L 59 1 499 34 864 25 635 57 1 448 32 813 247 112 56 310P 59 1 4...

Страница 9: ...d here Tacit L in W in H in L mm W mm H mm Watts 56 050L 22 22 5 9 559 572 229 800 56 050P 22 22 5 9 559 572 229 800 56 100L 27 24 5 10 686 622 254 1 250 56 100P 27 24 5 10 686 622 254 1 250 56 125L 2...

Страница 10: ...Tacit 8 User Manual 10 Remote Fan Module Dimensions and Mounting Tacit 050 150...

Страница 11: ...Tacit 8 User Manual 11 Remote Fan Module Dimensions and Mounting Tacit 210 and Up...

Страница 12: ...PORTANT SAFETY NOTICE Installer must ensure that all mounting points are secure and conform to local safety regulations Tempest Lighting Inc accepts no responsibility for damage or injury arising from...

Страница 13: ...e width on the opening side Enclosure Tilt Enclosure may be tilted up to 10 up or down Enclosure must NOT be tilted to left or right This may lead to equipment damage and personal injury Note These li...

Страница 14: ...xhaust Air Duct Tacit s powerful variable speed remote blower must be located in an adjacent space out of earshot of the audience and blowing warm exhaust air either into a ceiling void or an air retu...

Страница 15: ...ssible Ducting should allow for minimum airflow rates Tacit 050 150 350cfm150 250 500cfm 0 25m3 S Tacit 310 and up 1000cfm 0 5m3 S Do not use flexible duct hose The internal corrugations impose signif...

Страница 16: ...ontrol box USE ONLY ELECTRICAL CABLE WITH COPPER CONDUCTORS Pull the fan wires through the exhaust duct or in a separate conduit as preferred Terminals are spring loaded so no torque setting is requir...

Страница 17: ...e held responsible for damage or injury caused by disregarding this notice Electrical Standards Important Tacit enclosures manufactured after July 2019 run on any electrical supply from 100 250VAC 50...

Страница 18: ...ower and signal cables to your enclosure ALWAYS RUN POWER AND SIGNAL CABLES IN SEPARATE CONDUITS Using the Conduit Knockouts Use a screwdriver to bend the inner conduit blank covers back inside the en...

Страница 19: ...ontrol Daughter Board Ethernet Daughter Board optional RS485 Comms Daughter Board DEC4 Motherboard Ground Earth Terminals AC Terminals Fan Power Supply Unit Remote Fan Terminal Block DC Fan Transition...

Страница 20: ...Ethernet Daughter Board RS485 Comms Daughter Board DEC4 Motherboard AC Terminals Remote Fan Terminal Block DC Fan Transition Board Fan Power Supply Unit Ground Earth Terminals Duplex IEC C13 Outlet Au...

Страница 21: ...closure and Projector must be rated for the same voltage Supply must be rated for projector current plus 500 watts Supply must be permanently ON Split feed Enclosure power FEED must be permanently ON...

Страница 22: ...th Ground wire to Ground Terminal Connect Enclosure feed to the terminals marked ENCLOSURE Connect Projector feed to the terminals marked PROJECTOR Open the Split Feed Wiring Kit it contains two short...

Страница 23: ...to comply with local electrical codes Terminal Screw Torque Setting 0 5Nm 4 5in lb for clarity internal wiring not shown Split Feed Enclosure 10A 200 208VAC Single Phase 2 hots 10A Neutral for 120V Au...

Страница 24: ...crew Torque Setting 0 5Nm 4 5in lb for clarity internal wiring not shown Split Feed Enclosure 10A 230VAC Single Phase L N Protective Earth ground Projector 230VAC Single Phase L N Fuse Circuit breaker...

Страница 25: ...tem configuration and firmware upgrade capability over Ethernet Requires 51 D4 23 EtherNode board in at least one enclosure 2 Tempest Enclosure Management Protocol TEMP a simple protocol for use by sy...

Страница 26: ...be changed with a web browser on port 80 at the DHCP assigned address Login to the home page using admin for user name as password The bridges may be discovered with a UDP broadcast on port 1500 and a...

Страница 27: ...uns and wildly distributed systems use a DMX RDM splitter make sure that it supports RDM and multiple cable runs Use the termination switch to terminate each RS485 cable run at the last enclosure on e...

Страница 28: ...Tacit 8 User Manual 28 Line Termination Switch Settings 1 DMX RDM control over RS485 2 TSM TEMP Control of an enclosure group via Ethernet 3 TSM TEMP Control of a single enclosure via Ethernet...

Страница 29: ...river for your device and prevent normal operation of the software JESE GetSet is licensed software and registered to a qualifying hardware component Qualifying components include a USB controller suc...

Страница 30: ...very option in the Settings menu Next click on the Node Button to open the Node Manager Click on the Connect Button to initiate a node discovery and populate the Node Manager with all USB and network...

Страница 31: ...up all EtherNodes and any other USB Devices clicking on the discovery button will initiate a global discovery of all Tempest Enclosures and any other RDM compliant responders detected in the system Fo...

Страница 32: ...gled between sizeable and full screen view with the scale view button The fields displayed in the window may be customized to suit the Enclosure configuration options and user preference From the sett...

Страница 33: ...sed To load firmware to the enclosures right click the entry in the main window and select Reprogram from the drop down window For additional details refer to the latest GetSet MV User Guide Remote Co...

Страница 34: ...15 Ethernet Adapter over an Ethernet network Download the Developer Guide at www tempest biz tech_support IMPORTANT Tempest warrants that if correctly implemented TEMP will provide a reliable and acc...

Страница 35: ...f outdoor equipment DEC4 monitors internal and external temperature humidity and lamp current at all times and uses this information to control the enclosure s lamp relay fan s and heater s It can rep...

Страница 36: ...d spots when projector is idle DEC4 constantly monitors the following parameters Projector Luminaire current Line Voltage External Temperature Internal Temperature Internal Relative Humidity DEC 3 3 s...

Страница 37: ...Humidity Sensor is connected and functioning custom applications only Fan Board is connected and functioning correctly blinking Optional Ethernet Board is connected and functioning RS 485 Comms Board...

Страница 38: ...Tacit 8 User Manual 38 Fan Transition Board Remote Fan Fuse 6 3A slow blow Spare fuse...

Страница 39: ...lamp relay in the event of a projector malfunction RDM Status Reporting over RS485 RDM Configuration settings may be changed remotely or at the enclosure user interface Control mode is recommended for...

Страница 40: ...UT appropriate to the projector and application a The UT must always be higher than the expected ambient temperature at the enclosure location for example in an air conditioned roomful of people the...

Страница 41: ...d or disconnected Lamp On ON Green Current sensing shows lamp is ON Lamp hour counter is running OFF Current sensing shows lamp is OFF Lamp hour counter is not running Lamp Relay ON Green Lamp relay i...

Страница 42: ...ntrol Interface is normally LOCKED To UNLOCK hold ESC and OK together for 5 seconds You are now in the CONTROL MENU Use to scroll up and down the menu Press OK to enter a menu item Use to set the item...

Страница 43: ...arting address in the range 001 to 510 1 Lamp Relay In Service Mode an addition two slots are available 2 Fan Duty Control 3 Heater Duty Control Note that the DMX control is designed using a SAFETY pi...

Страница 44: ...0 10 C SET TEMP UPPER maximum desired daytime temperature default 45 C permissible range 25 50 C Zen and Tacit enclosures Adjust the UPPER TEMPERATURE setting as desired to balance cooling versus fan...

Страница 45: ...Set Fan Function SET FAN TYPE ID For Tacit choose Fan Type 270 For Zen choose Fan Type 140 SET FAN MIN DUTY This sets the minimum fan duty cycle speed Start by choosing the lowest value for the Fan T...

Страница 46: ...ture in degrees C or F c External Temperature custom enclosures with external temperature sensors only d PCB temperature this will usually be significantly higher than air temperature e Voltage line V...

Страница 47: ...ESE RDM TRI interface Fan board firmware is extremely simple and is unlikely to require updating RS485 Board 51 485 firmware may be updated over an RDM network using JESE GetSet software and a JESE RD...

Страница 48: ...he first time using JUST the PC MUST be connected to a live System Control Board for the installation to complete correctly 3 Run JUST and select the top left USB connection Icon Select the DEC4 from...

Страница 49: ...ct the Upload Firmware option Select the file Icon and navigate to the firmware file to upload 5 On selection the firmware upload will begin and run until complete 6 On completion of the upload dismis...

Страница 50: ...t 8 User Manual 50 7 The details of the SCB and firmware version may be viewed and verified by selecting the Device Information option 8 Close the application and disconnect the USB Cable from the SCB...

Страница 51: ...able for download from www tempest biz tech_support Powered Target DEC4 with 51 485 RS485 communication interface card Installation Procedure 1 If not already installed install a copy of GetSet To ens...

Страница 52: ...atively with a USB power adaptor connected to the USB Port on the SCB 5 On older revisions of DEC Firmware if the elected DEC DATA MODE is set to RS485 TEMP select RDM MONITOR mode using the DEC user...

Страница 53: ...ted item in the list view and select Reprogram from the popup menu This will open the firmware upload tool 8 In the Firmware upload handler search for a file to upload by clicking the file icon Find a...

Страница 54: ...rocess The upload will the start 10 On successful completion of upload and restart the firmware upload is complete Repeat from stage 8 to 11 for each additional file to upload On completion of the upl...

Страница 55: ...TA MODE for each enclosure as follows RDM MONITOR ONLY To view status information over RDM RDM CONTROL To monitor and over RDM and control the Lamp Projector relays via DMX If the enclosures are conne...

Страница 56: ...es depending on the size and orientation of your enclosure 1 Tacit 56 050 150 Landscape 2 Tacit 56 210 and up Landscape 3 Tacit 56 050 150 Portrait 4 Tacit 210 and up Portrait 5 Projector specific mou...

Страница 57: ...FU Kit below Projector Mounting Tacit 050 150 Landscape Feet up Kit The feet up kit 52 FU may be used in fixed or slide mounting enclosures The kit comprises two platforms adjustable in height to 25 5...

Страница 58: ...d washers provided The projector bars mount to a special box frame mount using hardware supplied Note it may be helpful to remove the projector feet For clarity the portrait mount is shown here outsid...

Страница 59: ...he carriage bolts washers and nuts provided to secure the clamps to the tray Tip if you need to remove the projector for service remove the two clamps nearest you leaving the opposite clamps in place...

Страница 60: ...for M6 M8 M10 and M12 threads 4 Bolt the four projector clamps to the projector tray using the eight M8 carriage bolts washers and nuts provided With feet adjustment 1 Leave the projector feet in pla...

Страница 61: ...NT Projectors with air inlets on the side of the projector chassis The inlet side MUST face down for optimal airflow Christie Crimson with portrait mounting kit and maximum downward tilt For upward ti...

Страница 62: ...ng on its back on a soft surface 1 Remove projector feet 2 Mount Projector Bars to projector base 3 Mount projector bars to L Brackets a Consider desired tilt angle UP DOWN or HORIZONTAL b Each mounti...

Страница 63: ...ng capacity Tempest provides a special internal fan box to hang on the right side of the projector to ensure delivery of adequate inlet airflow required for landscape versions only Install the Fan box...

Страница 64: ...ackets and mounting bars to the M12 threaded holes in the projector chassis as shown 3 NOTE the holes in the triangular bracket are set 1 5 apart so you can set the projector either horizontal or tilt...

Страница 65: ...to observe these minimum spacing requirements Back of projector to front of Wiring Box 75mm 3in Left side of projector to inside of Tacit left insulation 75mm 3in Portrait Orientation In portrait app...

Страница 66: ...es of the chimney are seated snugly around the projector lamp exhaust a vertical slot in the back of the projector Failure to follow this step will very likely lead to hot air recirculating and seriou...

Страница 67: ...ector 2 Mount the gooseneck temperature sensor arm to a projector tray slot close to the projector inlet using the hardware shown here 3 Bend the gooseneck arm so that the temperature sensor is just o...

Страница 68: ...nt above Connect Projector and Aux Equipment 1 Feed the projector power and signal cables through the cable management track 2 Connect the projector power cable into the 3 Connect all cables and test...

Страница 69: ...2 IEC 60320 C19 20Amp C19 a 56 210 x b 56 250 x c 56 320 x 3 IEC 60309 formerly IEC 309 often known in North America as Pin Sleeve 30 32A 2P E 230V blue a 56 310 x b 56 324 x c 56 400 x d 56 450 x 4 I...

Страница 70: ...Zen user interfaces are mounted on the projector tray For setup and service it will be convenient to angle the display to be visible from the side when the enclosure door is open You can also rotate t...

Страница 71: ...rojector is used If the filter becomes clogged the temperature inside the enclosure will start to rise This is an indication that the filter must be cleaned or possibly replaced Part Numbers 57 IFL 11...

Страница 72: ...ve the controller may not operate correctly A defective sensor will result in one of three messages appearing on the DEC user interface If you see any of these messages contact Tempest for a replaceme...

Страница 73: ...H 5 RH 100 or RH there is a sensor fault Contact Tempest for a replacement sensor Dirt Debris inside enclosure 1 Filter is either missing or damaged 2 Filter is not properly seated 3 Side panels or ba...

Страница 74: ...above ii to any Goods that have been subject to misuse abnormal service or handling or altered or modified in design or construction iii to any Goods repaired or serviced by any person other than Sel...

Страница 75: ...daptor connected to the DEC DMX connectors your DEC may be configured and monitored over an IP network Please contact factory for ordering information Physical Layer 1 EITHER Use a 51 EN Ethernet daug...

Отзывы: