Tacit 8 User Manual
45
Set Lamp On Point
The lamp current at which DEC detects the projector/luminaire lamp is running. Default is 1 Amp, which allows for
most equipment fans and power supplies to run without changing the air in the enclosure. Lamp on point may be
set in 0.1 Amp increments between 0.2 Amps and 2.0 Amps.
If the enclosure fans never turn off, the Lamp On point is probably set below the standby current draw of the
projector/luminaire. Check the standby current draw on the display and set the Lamp on Current higher.
Reset Lamp Hours
Reset each time you change the lamp in the projector.
Make this a part of your maintenance instructions.
Set Fan Function
SET FAN TYPE ID
For Tacit, choose Fan Type 270
For Zen, choose Fan Type 140
SET FAN MIN DUTY
This sets the minimum fan duty cycle (speed)
Start by choosing the lowest value for the Fan Type selected.
Enclosure fans will run at this speed when the enclosure senses that the projector is on.
If the projector overheats in the first ten minutes of operation, increase the minimum duty cycle setting until this
does not happen.
Fans will speed up as needed to maintain the UPPER TEMPERATURE selected (see above).
Adjust the UPPER TEMPERATURE setting as desired to balance cooling versus noise:
Lower Temperature = faster fan speed = more fan noise
Higher temperature = slower fan speed = less fan noise
SET FAN TEST
To test the enclosure fan(s), press [OK]
The enclosure fan will run
The Display Fan LED lights green
DEC Beeps
To stop the fan test, press [ESC]
Содержание Tacit 8 56.050L
Страница 6: ...Tacit 8 User Manual 6 Approvals China...
Страница 10: ...Tacit 8 User Manual 10 Remote Fan Module Dimensions and Mounting Tacit 050 150...
Страница 11: ...Tacit 8 User Manual 11 Remote Fan Module Dimensions and Mounting Tacit 210 and Up...
Страница 38: ...Tacit 8 User Manual 38 Fan Transition Board Remote Fan Fuse 6 3A slow blow Spare fuse...