74
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
-
Enable/Disable (ID=1101)
iButton List (ID=1610-1659)
U8
8.6.11.4
AutoGeofence event Priority (ID=1103)
Parameter defines AutoGeofence event priority: 0 is low, 1 – high;
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
1
Enable/Disable (ID=1101)
AutoGeofence event generating
(ID=1104)
U8
8.6.11.5
AutoGeofence event generating (ID=1104)
Generate event: 0 – no event, 1 - on entering zone; 2 – on exiting zone; 3 – on both;
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
3
2
Enable/Disable (ID=1101)
AutoGeofence event Priority
(ID=1103)
U8
8.6.11.6
Radius (ID=1105)
Parameter represents radius of circle with center device coordinates after activating
AutoGeofence feature.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1000000
100
Enable/Disable (ID=1101)
Deactivate by (ID=1100)
U32
8.6.12
iButton List (ID=1610-1659)
Read 5.4.4.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
FFFFFFFF
FFFFFFFF
-
Digital Output No.2 usage
scenarios (ID=1601)
Deactivate by (ID=1100)
U64
8.7
I/O parameters
I/O properties are additional data sources which are recorded along with usual GPS data.
8.7.1
I/O#1 property parameter (ID=1300)
Parameter defines I/O property value. Possible values: enabled (1), disabled (0).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
-
I
/O#1
priority
(ID=1301)
I/O#1 High level (ID=1302)
S8
Содержание FM1100
Страница 1: ...FM1100 User Manual v1 31 ...
Страница 10: ...10 Figure 1 FM1100 view dimensions tolerance 2mm ...
Страница 31: ...31 Figure 23 Dual SIM connection algorithm ...