50
Note: I/O element’s “Movement sensor” Averaging constant is interpreted as
Start Move Timeout in seconds (from 1 to 59).
Start Move Timeout – is a time interval required for movement sensor to be in
the moving state, to consider vehicle as moving.
5.16.1
Monitoring
I/O monitoring starts after enabling I/O element and setting up I/O parameters as it is
shown below:
Figure 47 I/O settings
5.16.2
Event Generating
Events happen when the value of enabled I/O intersects thresholds (enter, exit or on both)
predefined by High and Low level thresholds. Table below defines all available values of I/O
settings.
Setting
Value
Priority
low, high
High level
maximum threshold
Low level
minimum threshold
Generate event
on interval enter, on interval exit, on both enter and exit
Average constant
1 – 2
32
(4 Bytes)
Figure 48 Digital Input event generation example