12
Note: Analog Input error margin can increase if temperature varies. If Analog
input is not connected FM1100 will still measure certain numbers and it
cannot be 0. This measurement is influenced by hardware components.
2.5
Absolute Maximum Ratings
VALUE
CHARACTERISTIC DESCRIPTION
Min.
Typ.
Max.
Unit
Supply Voltage (Absolute Maximum Ratings)
-32
32
V
Drain-Source clamp threshold voltage (Absolute
Maximum Ratings),
(
I
drain
= 2mA
)
36
V
Digital Input Voltage (Absolute Maximum Ratings)
-32
32
V
Analog Input Voltage (Absolute Maximum Ratings)
-32
32
V
3
CONNECTION, PINOUT, ACCESSORIES
3.1
How to insert SIM card into FM1100 device:
Gently open FM1100 case using screwdrivers