where:
NN = 1 through 20 attempts to enter an invalid password.
(Default = 5)
Function 28: Prevent Duration
This function sets the number of minutes Prevent (Function 25) remains active
by specifying the number of minutes (1 through 20) that Prevent (Function 25)
will be in effect before allowing any caller to enter a valid password.
*28*MM#
where:
MM=number of minutes 1-20, (Default = 5)
Function 34: Reseize Code
This feature works in conjunction with Function 6.
*34*N*DDD#
where:
N is the number of digits in the control code
DDD can be 0, 2 or 3 digits in length, valid entries are 0-9, * or #
(Default=**)
If N=0, the feature is disabled
Function 35: Switchhook Flash Code
This feature is used to send a switchhook flash.
*35*N*DDD#
where:
N is the number of digits in the control code, 0=disabled
DDD can be 0, 2- 3 digits in length, valid entries are 0-9, * or #
(Default=*#)
Function 36: Access Programming Mode
This feature is used to enter programming mode.
*36*N*DDD#
where:
N is the number of digits in the control code
DDD can be 0, 2 or 3 digits in length, valid entries are 0-9, * or #
(Default=#*)
If N=0, the feature is disabled
Function 37: Disconnect Code
*37*N*DDD#
where:
N is the number of digits in the control code
DDD can be 0, 2 or 3 digits in length, valid entries are 0-9, * or #
(Default=# #)
If N=0, the feature is disabled
Chapter 5: Programming the M-106E
106E-101, Issue 1
Page 31