To disable answer tone, enter:
*2*0#
Function 3: Set Answer Tone and Voice Level
This function sets levels of both answer tone and voice. The levels can be
adjusted upward or downward from the default:
*3*L#
where:
L = 1 to 3:
1 sets the level to -16 dBm
2 sets the level to -10 dBm (Default)
3 sets the level to -4 dBm
Function 4: Set User Timeout
This function enables you to program the M-106E to disconnect the user after
the specified time limit. Times can be set separately for each user, or a single
timeout for all users can be set with one command.
Note:
If passwords are disabled, the unit will use the timeout value stored
for user number 25.
To set timeouts for specific users, enter:
*4*UU*TT#
where:
UU = the user number (1 or 2 digits)
TT= the timeout in minutes (1 to 99 minutes) (Default = 99)
To assign timeout (TT) to all users, enter:
*4*0*TT#
To assign “no timeout” to a user, enter:
*4*UU*# (or *4*UU*0#)
Note:
The time specified is the total time for each M-106E access. That is, the
timer does not reset with each retrial.
Function 6: Reseize Duration
This function sets the amount of time the M-106E remains on-hook when
Function 34, Reseize Code is sent or if set to 0, disables the reseize function.
*6*TT#
where:
TT=0, 5-30 (Default = 20 seconds)
The reseize duration is measured in tenths of a second. When TT=20, the
reseize duration is two seconds. This function works in conjunction with
Function 34, which assigns the Reseize Code.
M-106E Reference Manual