FlexSym-ONT205-Installation-Guide
Page 11 of 38
LED Behavior
LED
Indications
Comments
Power
Green
Input power is good to the ONT
Dark
Power is off to the ONT or power unit has failed
PON
Red
The PON is currently down, ONT is not receiving a signal from the OLT
Green Blink
Fast
The PON is up and ONT is attempting to register on the PON. If Auto
Configuration is not enabled, use Unknown ONT option on the Panorama PON
to register ONT.
Green Blink
Slow
The board is performing a software download.
Green
The PON is up and operating normally.
Dark
The ONT is booting
GE1-
GE4,
MG5
Green
• Link
(Up)
• PoE
(No PD Detected)
• Data
(No data detected)
Green Blink
• Link
(Up)
• PoE
(No PD Detected)
• Data
(Data detected)
Amber
• Link
(Up)
• PoE
(Powering PD)
• Data
(No Data Detected)
Amber Blink
• Link
(Up)
• PoE
(Powering PD)
• Data
(Data Detected)
Dark
The Ethernet Port is disabled or link is not detected
Manual Controls and Switches
The ONT has only one user-operable control:
•
Reset
–
This momentary pushbutton switch resets the ONT
The Reset switch pushbutton is accessible through a small hole on the right-hand side
of the unit (when viewed from the front).