13
Arming is not allowed if any zone is active
: if enabled, the module cannot be
armed if any of the zones is activated.
Maximum Alarming time
: can be adjusted between 5 and 25 minutes, means how
long should the module make attempts to report an event through GSM. When this
time expires and there are still calls or SMS to be performed for the given event, the
module will cancel the alarm process and will not make any more attempts of
reporting this specific event. This only refers to this specific event, calls and SMS
messages initiated by other new events will continue to be reported.
Maximum number of alarms per zone
: it can be set between 0 and 25, how many
alarms to be accepted from one zone. This makes possible to avoid a faulty zone to
occur alarms continuously. Disarming and rearming the system re-enables the zone,
then alarms are accepted again, but only the maximum number of alarms, according
to the setting. In case of setting value
0
, alarms are not limited.
Limitation duration
: it can be adjusted between 0 and 24 hours, how long the
module should ignore alarms of the specific zone which has reached the limitation
value entered at "
Maximum number of alarms per zone
" option. When this period of
time expires, the alarm counter is reset automatically and the zone becomes
monitored again. This limitation option is only available in „
Always armed
” mode.
Test report frequency
: the frequency of test report messages can be set in hours
(0-255). This means the module will send test reports in the intervals set here.
If value
0
is entered, the module does not send test reports.
Test report time
: here the time of test reports can be specified in hh:mm format or on
the left of the field the hours and on the right the minutes can be adjusted using the
arrows. The module takes this time into consideration on the first day of every month,
which means at this time of the first day of every month it sends a test report, then the
followings are sent again in the intervals set at frequency, and so on. On the first day
of the following month it will send a test report again at the given time of day.
Send test report now
: sends a test report immediately when pressed
Internal clock setting
: this setting is only available for module versions prior to v3.0 !
In versions higher than v3.0 this option has been replaced with time synchronization
feature through the programming software.
2.6 Changing the module’s password
To change the access password of the module, press the lock button and fill in the
fields according to the meaning, then press
OK
.
If the old password is forgotten, then it is necessary to reset the module settings in order
to reset the password as well. Module reset can be performed via SMS, that is described
in the “
Remote control and status query through SMS
” chapter on page 16.