2.5.4.1  Setting phone numbers through SMS 

The phone numbers can be set, replaced or erased also by sending an SMS to the 
module's SIM card from phone numbers configured in the module, containing the 
following commands: 
 

Setting 

SMS command 

Specification 

Module response

User phone 
numbers 

U

X

=

phone number

#

 

Substitute "X" with the 
ordinal number of the 
user phone number 
wished to be set or 
replaced (1,2,3 or 4) 

USER PHONE 
NR. CHANGED. 

Monitoring 
station phone 
numbers 

C

X

=

phone number

#

 

Substitute "X" with the 
ordinal number of the 
monitoring station phone 
number wished to be set 
or replaced (1 or 2) 

CENTRAL 
PHONE NR. 
CHANGED. 

Phone numbers 
for SMS 
forwarding  

S

X

=

phone number

#

 

Substitute "X" with the 
ordinal number of the 
SMS forwarding phone 
number wished to be set 
or replaced (1 or 2) 

SMS FORWARD 
NR. CHANGED. 

U

X

=#

USER PHONE NR. 
CHANGED.

 

C

X

=#

CENTRAL PHONE 
NR. CHANGED.

 

Erasing 
previously set 
phone numbers 

S

X

=#

Substitute "X" with the 
ordinal number of the 
phone number wished to 
be erased (1-4 for users, 
1-2 for others) 

SMS FORWARD NR. 
CHANGED.

 

 

The commands are also accepted by the module from phone numbers which are not 
configured in the module, but in this case the module password is requested to be entered 
in the command after the parameters, in the following way: 
e.g. 

U

X

=

phone number

, PWD=1111#

 . The procedure is the same if the command is 

sent from a phone number which is set in the module, but for which "0 - None." option is 
assigned at Caller ID setting, because with this setting the given phone number is 
considered unauthorized to perform remote settings, therefore password is required. 

 

Commands must always start with star "

" and respectively end with hash "

#

" character. It 

is also possible to send more commands in one SMS, but the entire message mustn’t 
exceed 160 characters. If the response SMS from the module would exceed 160 
characters, only the first 160 characters are transferred. In case of making typing or 
command mistakes, the following response SMS will be received: "

SYNTAX ERROR!

" and 

the command(s) will not be executed. 

 

Example: 

 

To set the first user phone number to be +36301234560, the first monitoring station 
phone number to be +36301234561 and the second SMS forwarding number to be 
+36301234562, type the following in the message: 

 

U1=+36301234560#

C1=+36301234561#

S2=+36301234562# 

 
To 

erase

 a previously set 

phone number

, leave the "

phone number

" part blank (eg.: to 

erase the second user phone number, type: 

U2=# 

). 

Содержание GSM Pager3 Z6

Страница 1: ...GSM Pager3 Z6 INSTALLATION AND USER MANUAL for module version v3 20 and up Document version 1 3 05 12 2013...

Страница 2: ...umber settings 10 2 5 4 1 Setting phone numbers through SMS 11 2 5 5 Alarm settings 12 2 6 Changing the module s password 13 2 7 Event log 14 2 8 Reading the module s version 15 2 9 Remote control and...

Страница 3: ...ion page The update procedure requires internet connection Here it can be also configured if the program should search for updates automatically upon each opening or this is performed manually by clic...

Страница 4: ...next to the USB icon in the upper right corner of the main window then the module version is displayed The program does not request the module password if the default password is set in the module 11...

Страница 5: ...the alarming time By keeping the mouse pointer above any cell of the table details of the specific event will be displayed If you wish to copy this content hold down CTRL button on keyboard and the de...

Страница 6: ...pens a window showing detailed information about the procedures running in the module only for troubleshooting Message flow can be started and stopped by pressing Start Stop button Messages can be sav...

Страница 7: ...active state of the zones can be set here Normally Open the input should be connected to V terminal to generate an event Normally Close the input should be connected by default to V terminal and then...

Страница 8: ...g 0 9 A B C D E F characters for reporting to monitoring station e g 130 alarm however this code is also used for restoration since the module will indicate automatically in the appropriate part of th...

Страница 9: ...means if it has been activated it will not deactivate itself can only be deactivated through phone call if enabled or will deactivate on disarm if Turn off Relay 1 on Disarm is set this function does...

Страница 10: ...e phone o 4 Arm arming the module with free call from version v3 10 o 5 Disarm disarming the module with free call from version v3 10 o 6 Arm Disarm first free call arms next free call disarms the mod...

Страница 11: ...are not configured in the module but in this case the module password is requested to be entered in the command after the parameters in the following way e g UX phone number PWD 1111 The procedure is...

Страница 12: ...ious one but operates the system inversely closed contact disarms open contact arms the module o 3 One kind of impulse arms the system with a closed contact impulse on input Z6 to V and performs disar...

Страница 13: ...n This limitation option is only available in Always armed mode Test report frequency the frequency of test report messages can be set in hours 0 255 This means the module will send test reports in th...

Страница 14: ...ks displayed in T1 T4 S1 S4 and C1 C2 columns o report processing in progress o reporting successful o R reporting already performed in other way therefore reporting is not needed o reporting failed o...

Страница 15: ...sword denied 4 low tone beeps 0 Disarm 3 beeps 1 Arm 6 beeps 2 Armed status query Disarmed 3 beeps Armed 6 beeps 4 GSM signal strength query Number of beeps according to the actual GSM signal strength...

Страница 16: ...ON PWD yyyy CRQ Activation of Relay1 bistable mode If needed substitute yyyy with the module password see specifications below R1 OFF PWD yyyy CRQ Deactivation of Relay1 If needed substitute yyyy with...

Страница 17: ...ed Permanent Relay1 activated permanently bistable mode Relay1 deactivated Relay1 deactivated Unauthorized User Wrong or missing password Module reset executed Module settings are restored to factory...

Страница 18: ...ulty Red blinks fast Green blinks slower Event transmission in progress Green blinks impulsely and slowly Red is not lit GSM network is available system is disarmed Green and red blink impulsely and a...

Страница 19: ...antenna or find a more suitable place for the module The antenna should be placed outside the box in case of installing the unit into a metal box where the measured GSM signal is the highest possible...

Страница 20: ...uency GSM 900 1800 MHz 850 1900 MHz Max relay output load 5A 24VAC DC GSM phone type Simcom SIM900 Dimensions 84 x 72 x 32mm Weight 200g packed 300g 5 2 Contents of the package GSM Pager3 Z6 terminal...

Отзывы: